End Feed Meter Feature Set Communications

Input Voltages (L‐L/L‐N) Current Per Phase (Max/Min) Voltage ‐ Per Phase (Max/Min) Neutral Current Power Factor Frequency

M20

M40

M6

M7

M9

M25

M26

M27

End Feed Current Monitoring (Modbus RTU)

End Feed Power Monitoring Advanced (SNMP) Modbus TCP / IP (Ethernet),  Modbus RTU (RS‐485),  Telnet, HTTP, HTTPS, SNMP, SMTP,  SSH Optional 802.11n Wi‐Fi

End Feed Power Monitoring Basic (Modbus RTU)

End Feed Power Monitoring Enhanced (Modbus RTU)

End Feed Power Monitoring Basic (Modbus TCP)

End Feed Power Monitoring  (Wireless)

End Feed Power Monitoring Basic (SNMP)

End Feed Power Monitoring Advanced (SNMP)

Modbus RTU (RS‐485)

Modbus RTU (RS‐485)

Modbus TCP (Ethernet)

Proprietary Wireless Mesh

347Vac L‐N / 600Vac L‐L   Calculated or Measured

400Vac L‐N / 690Vac L‐L   Calculated

400Vac L‐N / 690Vac L‐L   Calculated

416Vac L‐N / 721Vac L‐L   Calculated

110‐240Vac L‐N / 240‐415Vac L‐L  

300Vac L‐N / 520Vac L‐L   Calculated or Measured

417Vac L‐N / 720Vac L‐L+10%   Calculated or Measured











  Active Power Only  (Total)















 (Total)   <0.2%   (need external buzzer/power  supply [relay]) (1) RJ‐45 Ethernet (TCP)

 (Total)

<0.5%   (need external buzzer/power  supply [relay]) (2) RJ‐11 (RTU) 

(Total and per phase)   (Total and per phase)  (Total and per phase)   <0.5%   (need external buzzer/power  supply [relay]) (2) RJ‐11 (RTU) 





<0.5% 

 (Total and per phase)   <0.5% 

 (Total and per phase)   <0.4% 

N/A N/A

Email Alerts 

Email Alerts 

(1) RJ‐45 Ethernet (1) RJ‐11

(1) RJ‐45 Ethernet (1) RJ‐11

12 Digit LED 4.3x4.3x2.57"/(ANSI 4")  N/A 100‐240Vac; 110‐300Vdc; 20‐ 60Vdc Schneider Electric Website Download

12 Digit LED 4.3x4.3x2.57"/(ANSI 4")  N/A 100‐240Vac; 110‐300Vdc; 20‐ 60Vdc Schneider Electric Website Download

12 Digit LED 4.85x4.85x4.65"/(Ansi 4")  N/A

N/A N/A N/A 

LCD‐Display With Blacklight 3.77x3.77x3.07"  N/A

LCD‐Display With Blacklight 5.66x5.66x3.18"  N/A

90‐265Vac; 100‐370Vdc; 18‐60Vdc Electro Industries Website Download

120/240Vac Packet Power Website Download

95V ‐ 240V AC; 100V ‐ 300V DC Janitza Website Download

20‐240Vac;20‐340Vdc Janitza Website Download

Modbus RTU (RS‐485)

480Vac max  Measured 



Power (Active, Reactive, Apparent) Demand (kWh) Voltage THD Current THD Accuracy

<1%

Alarm Output



Ports Display Size/(Cutout) CTs (Standard 5A) CTs (2 mA) Power Supply Voltage Manufacturer Software Included

(2) RJ‐11, (1) RJ45 Ethernet 

 (Total and per phase)   <0.5%  Email Alerts 

Optional N/A N/A 

(1) RJ‐45 Ethernet (2) RJ‐11 Optional LCD‐Display With  Blacklight 4.75x4.75x2.00"  

120/240Vac; 12Vdc StarLine Embedded Webpage

20‐480Vac StarLine Embedded Webpage

Modbus TCP / IP (Ethernet),  Modbus TCP / IP (Ethernet),  Modbus RTU (RS‐485),  Modbus RTU (RS‐485),  HTTP, SNMP, SMTP, SNTP, TFTP,  BACnet, HTTP, SNMP, SMTP, SNTP,  TFPT, FTP and DNS FTP and DNS

M20

Branch Circuit Meter Feature Set Communications

Input Voltages (L‐L/L‐N) Current Per Phase (Max/Min) Voltage ‐ Per Phase (Max/Min) Neutral Current Power Factor Frequency

Branch Circuit Current Monitoring  (Plug‐In Units)

Modbus RTU (RS‐485)

480Vac max  Measured 

Power (Active, Reactive, Apparent) Demand (kWh) Voltage THD Current THD Accuracy

<1%

Alarm Output



Ports Display Size/(Cutout) CTs (Standard 5A) CTs (2 mA) Power Supply Voltage Manufacturer Software Included

(2) RJ‐11, (1) RJ45 Ethernet  Optional N/A N/A  120/240Vac; 12Vdc StarLine Embedded Webpage

M40

M22

M23

M25

End Feed Power Monitoring Branch Circuit Power Monitoring  Branch Circuit Power Monitoring  Branch Circuit Power Monitoring  Advanced (SNMP) (Plug‐In Units) (Plug‐In Units) (Plug‐In Units) Modbus TCP / IP (Ethernet),  Modbus RTU (RS‐485),  Modbus RTU (RS‐485) Modbus TCP and SNMP (Ethernet) Proprietary Wireless Mesh Telnet, HTTP, HTTPS,SNMP, SMTP,  SSH Optional 802.11n Wi‐Fi 347Vac L‐N / 600Vac L‐L 300Vac L‐N / 120‐480Vac L‐L 300Vac L‐N / 120‐480Vac L‐L 110‐240Vac L‐N / 240‐415Vac L‐L         Calculated or Measured Calculated Calculated  

 

 

 















<0.5%  (need external buzzer/power  supply [relay]) (2) RJ‐11 (RTU) 

<0.5%  (need external buzzer/power  supply [relay]) (1) RJ‐45 Ethernet (TCP)

<0.5% 

Optional N/A   Phase A & B or Phase A & N MeasurLogic Website Download

Optional N/A   Phase A & B or Phase A & N MeasurLogic Website Download

N/A N/A

 (Total and per phase)   <0.5%  Email Alerts  (1) RJ‐45 Ethernet (2) RJ‐11 Optional LCD‐Display With  Blacklight 4.75x4.75x2.00"   20‐480Vac StarLine Embedded Webpage

N/A N/A

 120/240Vac Packet Power Website Download