Scarborough Fire Department Scarborough, Maine Standard Operating Procedures Book: Chapter: Subject: Revision Date: Approved by:

Emergency Operations Medical Emergencies 3415 - Use of Carbon Monoxide Patient Monitors 8/31/2007 B. Michael Thurlow

PURPOSE The purpose of this policy is to illustrate the dangers of Carbon Monoxide poisoning and to outline requirements and procedures for Carbon Monoxide patient monitoring as an assessment tool to provide high quality patient care. BACKGROUND INFORMATION Carbon Monoxide (CO) poisoning is one of the single most common poisoning exposures in the United States. Carbon monoxide, or CO, is an odorless, colorless and tasteless gas that can cause sudden illness and death, and is found as a by-product gas of combustion from gasoline engines, camp stoves, lanterns, burning charcoal and wood, gas ranges, heating systems, generators and poorly vented chimneys. Structural fires are another common source of CO exposure for both victims and fire fighters. Carbon monoxide from these sources can build up over time in poorly ventilated environments to a toxic level that can be inhaled by humans and animals. Though all humans and animals are at risk for carbon monoxide poisoning, pregnant women and their fetuses, infants, and people with chronic heart disease, anemia, or respiratory problems are more susceptible to its effects. CO toxicity causes impaired oxygen delivery and utilization at the cellular level. CO affects several different sites within the body but has its most profound impact on the organs with the highest oxygen requirement (e.g., brain, heart). Misdiagnosis commonly occurs because of the vagueness and broad spectrum of complaints. Symptoms often are attributed to a viral illness, frequently “the flu” in winter months. It is important to remember that symptoms may not correlate well with measured HbCO levels. POLICY Since CO poisoning is easily misdiagnosed as flu-like symptoms, fatigue or other general complaints, the Masimo RAD 57 CO patient monitor shall be used: A. On ALL patients that require the use of SpO2 monitoring. B. Whenever multiple patients in the same building present with similar signs and symptoms C. As part of firefighter monitoring in the rehab sector at structure fires.

3415 – Use of Carbon Monoxide Patient Monitors – Page 2.

PROCEDURES A. SECURE AIRWAY - As appropriate for license level, secure airway utilizing oral or nasal airway, Combitube or endotracheal tube. Confirm placement of endotracheal tube with end-tidal CO2 detector and esophageal detector device. B. OXYGEN - Provide 100% Oxygen via non-rebreather mask, bag-valve-mask or approved ventilator. C. MONITOR - Monitor and treat EKG rhythm as appropriate. Monitor Sp02 (pulse oximeter will read falsely high in the presence of Carbon Monoxide) and SpCO. Two (2) SpCO readings must be obtained 10 minutes a part. D. ASSESS - Determine Carboxyhemoglobin level if possible. Based on reading: a. If patient measures SpCO 0-3% No further evaluation of SpCO needed b. If patient measures SpCO > 3% - Reassess i. Altered LOC or Neurological impairment or SpCO > 25% 1. Treat with 100% oxygen and transport to closest most appropriate hospital (consider hyperbaric facility) ii. No Altered LOC and SpCO < 25% 1. SpCO > 12% - Treat with 100% oxygen and transport 2. SpCO < 12% - Symptoms of CO? a. Yes – Treat with 100% oxygen and transport b. No – No further medical evaluation of SpCO needed E. IV/IO ACCESS - As appropriate for license level, IV TKO. F. DOCUMENT - SpCO readings on the Maine EMS run report in the narrative section. If the patient is suspected to be a victim of CO poisoning, complete an EMS Patient CO Monitoring Form, make a copy and leave it with the ED staff and submit the original to be filed with department’s copy of the run report. SCOPE The RAD-57 Patient Carbon Monoxide Monitor is another patient assessment tool. Its readings alone should not be used to diagnose a patient with Carbon Monoxide poisoning. When assessing and treating patients with any of the signs and symptoms of Carbon Monoxide poisoning, other etiologies of the presenting illness must be considered. RESPONSIBILITY It is the responsibility of the EMS provider providing care, to use the CO patient monitor as outlined in this policy. REFERENCES A. Boston EMS SOP “Use of the Rad-57 for Carbon Monoxide Exposure in the Prehospital B. RAD-57 EMS and FIRE Quick Reference Guide for RAD-57 C. Masimo “The Odorless Killer” AHVP-464-0306 Fire and Emergency Training Network

Scarborough Fire Department

Aug 31, 2007 - over time in poorly ventilated environments to a toxic level that can be inhaled by humans and animals. Though all humans and animals are at ...

92KB Sizes 0 Downloads 203 Views

Recommend Documents

Scarborough Fire Department Scarborough Fire ...
c. Written Reprimands d. Suspensions e. Demotions f. Termination. G. The department does not profess to provide employees with an all inclusive list of specifically prohibited behavior. Employees are expected to have a reasonable perception of what c

Scarborough Fire Department
Scarborough Fire Department. B. Michael Thurlow, Fire Chief. Phone: 207-883-4542. 246 Route 1, Scarborough, ME 04074. Fax: 207-730-4270. GENERAL ORDER. TO: ALL PERSONNEL. ORDER #: 16-005. DATE ISSUED: 03/22/2016. SUBJECT: USE OF ANCILLARY VEHICLES FO

Scarborough Fire Department
Chapter: Fire Department Organization. Subject: 1150 – Student Live-In Firefighter Program. Revision Date: 07/17/2013 rev. 04/10/2015. Approved by: .... Completed evaluations will be forwarded to the student live-in advisor. ... X. Students wishing

Scarborough Fire Department
POLICY. The Scarborough Fire Department will pay Per-Diem firefighters based on a pay plan which ... c. A request for review of a members pay rate shall be made in writing to the Fire. Chief's office. The request must include the Training Level Certi

Scarborough Fire Department Scarborough, Maine
Mar 27, 2008 - Dispatchers. District Chief. Captains. Paramedic Lieutenant. Lieutenants. Full Time Firefighter/EMTs. On-Duty Station Leader. Per Diem EMTs & ...

Scarborough Fire Department
Scarborough Fire Department. B. Michael Thurlow, Fire Chief. Phone: 207-883-4542. 246 Route 1, Scarborough, ME 04074. Fax: 207-730-4270. GENERAL ORDER. TO: ALL PERSONNEL. ORDER #: 17-006. DATE ISSUED: 02/03/2017. SUBJECT: FIRE REPORT ASSIGNMENT & COM

Scarborough Fire Department
Book: Organization. Chapter: Personnel, Policies & Procedures. Subject: 1355 – Quality Assurance and Improvement Plan. Revision Date: 09/23/2016. Approved by: B. Michael Thurlow ... process is one of the few which allows disclosures of protected he

Scarborough Fire Department
the best interest of patient care and safety of dispatched apparatus and personnel. Ambulance personnel or supervisors responding to calls without an engine assist may request additional resources if it becomes evident that those resources may be nec

Scarborough Fire Department
implementation and recording of all department training including schools, classes, day training, or other training ... Hold a Municipal Instructor Certification issued by Maine Fire Training & Education. c. Hold an ... Training Program is a progress

Scarborough Fire Department
B. Pay for all approved training time at the firefighters normal pay rate. C. Longevity pay steps to reward ... plan which rewards members for training, longevity, EMS licensure level, membership on specialty teams, and .... Signature space for membe

LEXINGTON VOLUNTEER FIRE DEPARTMENT SCHOLARSHIP ...
Whoops! There was a problem loading more pages. Retrying... LEXINGTON VOLUNTEER FIRE DEPARTMENT SCHOLARSHIP.pdf. LEXINGTON VOLUNTEER ...