IJRIT International Journal of Research in Information Technology, Volume 2, Issue 4, April 2014, Pg: 677- 681

International Journal of Research in Information Technology (IJRIT) www.ijrit.com

ISSN 2001-5569

Real Time Patients Monitoring System using Optical Sensor on Single FPGA Ms. Sonal Tayade1, Mr. S. B. Patil2 1

2

PG student, Electronics Department, Shri Sant Gajanan Maharaj College of Engineering Shegaon, Maharashtra, India [email protected]

Professor, Electronics Department Name, Shri Sant Gajanan Maharaj College of Engineering Shegaon, Maharashtra, India [email protected]

Abstract This paper describes the design of real time patient monitoring system using different types of sensors and very high speed hardware description language (VHDL). Patient monitoring system consist of equipment, devices and supplies that measure, display and record human body parameter including heart rate and body temperature. Heart rate of the patient is measured using infrared sensor that senses the change in blood concentration in finger artery at the time when heart pumps the blood. Body temperature of patient is measured using LM35 sensor. We have tried to make a system which may give information of patient’s physical situation and help to provide emergency treatment. This design has been implemented in Xilinx FPGA board and monitoring and control system has been developed.

Keywords: Heart rate, body temperature, IR sensor, LM35 sensor, FPGA.

1. Introduction Heart rate detection is one of the very important parameter of human cardiovascular system. Heart rate of the healthy adult is about 72 beats per minute (bpm). Babies have much higher rate around 120 beats per minute. Heart rate is increases gradually during exercise and tends to decrease slowly at normal after exercise. The rate on which pulse tends to normal is an indication of fitness of a human being. Heart rate can vary according to need of muscles to absorb oxygen and excrete carbon dioxide changes during exercise or during rest. It also change based on the individual fitness, age and genetics. A heart rate monitor system is a device that takes sample of heart beats and computes the beats per minute so that the information can be easily track hearts position. There are two types of methods to measure heart rate electrical and optical. In this paper the design of low powered heart rate measurement is presented that provided the accurate measurement of heart rate using optical technology. We use the optical technology using IR sensor (infrared LED) and photodiode to measure the heart rate within seconds using finger artery.

Ms. Sonal Tayade,

IJRIT

677

IJRIT International Journal of Research in Information Technology, Volume 2, Issue 4, April 2014, Pg: 677- 681

Temperature is a measure of the degree of heat intensity level. The temperature of a body is deals with its molecular excitation. The temperature difference between two points indicates a potential for heat to move from the warmer to the colder point. The human body’s temperature varies from day to day, and from time to time, but these fluctuations are small, no more than then 1 .It is one of main indicators of normal functioning and health. The nature of human body is to keep its temperature within a safe value in spite of large variations in temperatures outside the body. Temperature is mostly considered to be a vital sign most notably in a hospital. This paper proposed a nonintrusive body temperature measuring system. The system estimates the deep temperature non-intrusively only when the patient is at rest, since the sensor is embedded in a neck pillow.

2. System Block Diagram Fig.1 shows the block diagram of the real time patient monitoring System using VLSI technology. Different body parameters such as heart rate and temperature are continuously monitored as well as controlled with this system. Various types of sensors are used to sense these bioelectrical signals. The signals obtained from the IR sensors are weak signals which are then amplified and converted into digital form using AVR Atmega8. Digital data is fed to the FPGA device. The little change in the amplitude of the reflected light can be converted into a pulse with proper signal conditioning circuit. The signal conditioning circuit consists of two identical active low pass filters with a cut-off frequency of about 2.34 Hz. This means the system is able to measure heart rate is about 150 bpm. The operational amplifier IC used in this circuit is LM358. It operates at a single power supply and provides back to-back output swing. The filtering is necessary to block any unwanted noises present in the signal. The gain of each filter stage is set to 101, giving the total amplification of about 10000. A 1 µF capacitor at the input of each stage is required to block the dc component in the signal. The equations for calculating gain and cut-off frequency are given (1) Fc= 1/ 2π Rf Cf Gain of each stage = 1+ Rf /Ri = 1+ 680 k / 6.8k =101

(1)

(2)

The LED is connected at the output blink every time a heartbeat is detected. ATMEGA8 has been programmed to detect signal of both the sensor and FPGA has been programmed to show the measured data. The LM35 temperature sensor has been used to measure the body temperature. The output pin of the LM35 sensor is connected to AVR Atmega8 to convert analog signal into digital form. This digital data is fed to the FPGA device.

Fig. 1 Sensor interface design Ms. Sonal Tayade,

IJRIT

678

IJRIT International Journal of Research in Information Technology, Volume 2, Issue 4, April 2014, Pg: 677- 681

3. Software Design The software can be divided into two parts: first one is the data acquisition from sensor with the help of Atmega8 the program written in C programming language & dumped into the controller using C compiler. The program contains the following: Conversion of analogue signals (heartbeat, body temperature,) to digital values and indication when microcontroller detects the pulse. Second one is data processing module receiving physiological data from the patient. For data processing program written in VHDL & dumped into the FPGA using Xilinx ISE tool.

Fig 2. Flow chart

3. Methodology 3.1 IR Transmitter and Receiver The hemoglobin molecules of blood absorb the infrared light. Each time when heart pumps, the volume of oxygen rich blood increases in the finger artery. Each heartbeat increases the concentration of blood in finger artery. The IR transmitter transmits an infrared light into the fingertip (placed over the sensor unit), and the IR receiver senses some of the portion of the light that is reflected back. The intensity of reflected light depends upon the blood concentration inside the finger artery. So, each heart beat slightly alters the amount of reflected infrared light that can be detected by the IR receiver. With a proper signal conditioning, this little change in the amplitude of the reflected light can be converted into a pulse. The pulses can be counted by the Atmega8 to determine the heart rate and also converted that analog signal into digital form for further processing. The IR Receiver picks an AC signal with some higher frequency noise. The filtering is necessary to block any higher frequency noises present in the signal. A Resistor is connected to the IR receiver to reduce the current drawn by the detector. If the intensity, of IR light is too high, then the reflected infrared light from the finger artery will be sufficient enough to saturate the transmitter all the time, and no signal will exist. So the value of the resistance connected in series with the Infrared transmitter is chosen to limit the current and hence the intensity of the transmitted infrared light.

3.2 Filtering and Amplification of Signal Ms. Sonal Tayade,

IJRIT

679

IJRIT International Journal of Research in Information Technology, Volume 2, Issue 4, April 2014, Pg: 677- 681

The desired signal can be extracted from the noisy signal using a low pass filter with cutoff frequency of about 2.34.The signal must be amplified for understanding and counting pulse rate by the AVR Atmega8. A two stage filter and amplifier circuit using LM358 Op Amp can be designed for this. This Op Amp is operated with 5 volts power supply. In the designed circuit, total gain is 10201. Values of Rf and Ri are 680 KΩ and 6.8 KΩ. The 1uF capacitors, which are connected in series to the inputs of each filter blocks the higher frequency noise from the signal

3.2 Body Temperature Sensing Unit The whole circuit uses 5 V at their positive terminals and negative terminals is connected to 0v (ground) .For body temperature monitoring, LM35 sensor has been used. It is a precision integrated circuit Temperature Sensor which is small and can be placed anywhere on the body to monitor temperature. LM35 has an output voltage linearly proportional to the Centigrade temperature. LM35 draws only 60 µA from the supply, it has very low self-heating of less than 0.1°C in still air. The LM35 is rated to operate over a −55°C to +150°C temperature range.

4. Actual Hardware Test Result Subject

Table 1 Designed Device Output

Standard Device Output

Person1 Person2 Person3 Person4 Person5 Person6 Person7 Person8 Person9 Person10 Mean

Relaxed Stage 66 61 69 70 72 68 62 71 73 67 67.9

Relaxed Stage 64 62 72 70 71 68 64 70 76 66 68.3

Stressed Stage 110 112 122 124 126 118 112 124 126 120 119.4

Stressed Stage 118 114 120 122 126 118 114 122 130 120 120.4

Percentage error (Er1) between mean heart rates in relaxed stage obtained from the designed hear rate and the standard heart rate monitor respectively is given by, Er1 = [(68.3 -67.9) x 100]/68.3 = 0.58 % < 1% Percentage error (Er2) between mean heart rates in stressed stage obtained from the designed hear rate and the standard heart rate monitor respectively is given by, Er2 = [(120.4 -119.4) x 100]/120.4 = 0.83 % < 1% Thus, it can clear from above table and the above calculations that the difference between the results of the mean values obtained from the designed heart rate monitor and that of standard heart rate monitor is less than 1% for both in the relaxed and stressed states respectively. Compared to the standard device, it can be seen that the designed is able to function and provide results satisfactorily.

Ms. Sonal Tayade,

IJRIT

680

IJRIT International Journal of Research in Information Technology, Volume 2, Issue 4, April 2014, Pg: 677- 681

5. Future Scope The device can be improved in certain areas as listed below 1. A graphical LCD can be used to display a graph of the change of heart rate. 2. Sound can be added to the device so that a sound is generated each time a pulse is received. 3. Parameter data can be saved and record can be generated. 4. Other body parameters can be added. 5. We can also send the output to a mobile phone and get it displayed on the mobile screen.

6. Conclusion Patient monitoring system is very useful for senior citizens and physically challenged people who are suffering from variation of Heart rate, body temperature and they can be treated from sudden trouble. Using this system we can adjust the minimum and maximum level of heart rate and body temperature, if the patient’s physical parameters exceed the levels then immediately the indication will be given with the help of alarm to the concerned doctor so that we can save the life of the patient. For this System to measure Heart Rate and body temperature project we can add sugar test, blood pressure, now-a-days which is a common disease for a human being.

Acknowledgment The author would like to express thanks and gratitude to Prof S. B. Patil, SSGMCE, Shegaon (Maharashtra) for helpful discussions and valuable guidance.

References [1] P. K. Gaikwad, “Development of FPGA microblaze processor and GSM based heart rate measurement”, IJCSMA, sept-2013 vol.1 issue3, pp.26-29, [2] Johevajille K. N Mazima, Michael Kisangiri, Dina Machuve, “Design of low cost blood pressure and body temperature interface ” IJESE , aug2013, vol.1, issue.10. [3] S. Sim, et al., "A nonintrusive temperature measuring system for estimating deep body temperature in bed" in Engineering in Medicine and Biology Society (EMBC), 2012 Annual International Conference of the IEEE, 2012, pp. 3460-3463. [4] N. Bugtai, et al., "Development of a Portable Heart Monitoring System” in TENCON 2012-2012 IEEE Region 10 Conference, 2012, pp. 16. [5] M.M.A. Hashem, Rushdi Shams, Md. Abdul Kader and Abu. Sayed, “Design and development of a heart rate measuring device using fingertip” 3rd IEEE International Conference on Computer and Communication Engineering (ICCCE'10), Kuala Lumpur, Malaysia, May 11-12, 2010. [6] T.Usui, A. Matsubara, and S. Tanaka, "Unconstrained and noninvasive measurement of heartbeat and respiration using an acoustic sensor enclosed in an air pillow," SICE 2004 Annual Conference, 2004, vol. 3, pp 2648-2651. [7] R.G. Landaeta, O.Casas, and R.P.Areny, “Heart rate detection from plantar bioimpedance measurements”, 28th IEEE EMBS Annual International Conference, 2006, pp. 5113-5116 [8] S.Rhee, B.-H. Yang, and H. H. Asada, "Modeling of finger photoplethysmography for wearable sensors” 21st Annual Conference and the 1999 Annual Fall Meeting of the Biomedical Engineering Soc. BMES/EMBS Conference, 1999. [9] T. Instruments, Datasheet LM35, Recuperado miercoles, vol. 27.

Ms. Sonal Tayade,

IJRIT

681

Real Time Patients Monitoring System using Optical ...

IJRIT International Journal of Research in Information Technology, Volume 2, ... 1PG student, Electronics Department, Shri Sant Gajanan Maharaj College of ...

69KB Sizes 9 Downloads 298 Views

Recommend Documents

75.WIRELESS SYSTEM FOR MONITORING AND REAL TIME ...
WIRELESS SYSTEM FOR MONITORING AND REAL ... CLASSIFICATION OF FUNCTIONAL ACTIVITY.pdf. 75.WIRELESS SYSTEM FOR MONITORING AND ...

Highly Sensitive Monitoring of Ru Etching Using Optical ...
Highly Sensitive Monitoring of Ru Etching Using Optical. Emission .... Another application of Ru emission is related to the chamber cleaning process applied ...

Highly Sensitive Monitoring of Ru Etching Using Optical ...
the gate electrode. Metals have low resistivity and high electron ... source of the emission is Ru atoms.5 Knowledge of the emission spectra is necessary to ...

StreamWeb: Real-Time Web Monitoring with ... - Semantic Scholar
Twitter streaming data, and that displays any messages including the specified keywords .... stored into relatively slow secondary storage such as a hard disk.

In-situ real-time monitoring of biomolecular interactions ...
cantilever surface, the negative control experiment was conducted by injecting BSA dissolved PBS solution into a liquid cell. The resonance behavior of our ...

In-situ real-time monitoring of biomolecular interactions ...
School of Advanced Materials Science and Engineering, Yonsei University, Seoul 120- ..... Resonant frequency shift due to virtual mass and quality factor for our.

Algorithms for Monitoring Real-time Properties
define this class, we distinguish between event propositions and state proposi- tions. ...... Conference on Foundations of Software Technology and Theoretical ...

real time perfusion and oxygenation monitoring in an ...
oxygenation ratio compared to traditional analysis techniques . ... package based on autocorrelation that is employed to obtain the perfusion and .... have become a standard monitoring device in hospital critical care units and surgical ..... (MLMC)

Real-Time Interactive Visual Port Monitoring and ...
visual monitoring and analysis of port connections. The goal is to provide more information than is currently available, from event logs, as to the actual activity ...

StreamWeb: Real-Time Web Monitoring with ... - Semantic Scholar
messages into what they call a “public timeline” if the users are making public “tweets” (the basic .... iPhone. By leveraging that location information with the tweets, ... Extensibility: The system needs to add and monitor additional data s

StreamWeb: Real-Time Web Monitoring with Stream ...
Nov 7, 2007 - International Business Machines Corporation 2011 ... 2 Tokyo Institute of Technology ... SPADE : Advantages of Stream Processing as.

Real-Time Detection, Tracking, and Monitoring of ...
Real-Time Detection, Tracking, and Monitoring of Automatically. Discovered Events in Social ... time event detection, tracking, monitoring ..... 6.4 Visual Analytics.

In situ real-time monitoring of biomolecular interactions ...
School of Advanced Materials Science and Engineering, Yonsei University, Seoul 120-749, .... Color online Resonant frequency shift due to virtual mass and.

Real-Time Monitoring of High Intensity Focused ...
the above acousto-optic effect, decreasing the drop in signal. In order to enable real-time detection of lesion formation, the signal-to-noise ratio is boosted by taking advantage of the. f i. d l i l di. Tissue motion is measured by “speckle track

Real-Time Monitoring of High Intensity Focused ...
However, real-time imaging of the tissue heating and lesion formation process is challenging ... Here we report on an approach to monitor HIFU lesions by means of changes in both optical .... optical properties of diffusive media by acousto-.

StreamWeb: Real-Time Web Monitoring with Stream ...
throughput, and MapReduce and Hadoop are unsatisfactory. The developer should be able to focus only on the analytical algorithms, perhaps selecting from ...

Real-Time Polymerase Chain Reaction Monitoring of ...
and entry into the soil environment between RR and nontrans- genic soybeans and also ...... Eichholtz, D. A.; Peschke, V. M.; Nida, D. L.; Taylor, N. B.; Kishore,.

Optical Image Stabilizing System using Multirate Fuzzy ...
Computer Science, ASRI Seoul National University, Seoul, Korea (e-mail: ..... integrator calculates an integral value of e, and the differentiator calculates a ...

SERVER MONITORING SYSTEM
Department of Computer Science and Information Technology ... SYSTEM” in partial fulfillment of the requirements for the degree of ... the period of last three and half years. .... CHAPTER 2: REQUIREMENT AND FEASIBILITY ANALYSIS .

A Monitoring System Using Wireless Sensor Network.pdf ...
A Monitoring System Using Wireless Sensor Network.pdf. A Monitoring System Using Wireless Sensor Network.pdf. Open. Extract. Open with. Sign In.

a self powering wireless environment monitoring system using soil ...
a self powering wireless environment monitoring system using soil energy 06874554.pdf. a self powering wireless environment monitoring system using soil ...

Open Vehicle Monitoring System - GitHub
Aug 14, 2013 - 10. CONFIGURE THE GPRS DATA CONNECTION (NEEDED FOR ...... Using the OVMS smartphone App (Android or Apple iOS), set Feature ...

Open Vehicle Monitoring System - GitHub
Feb 5, 2017 - GITHUB. 10. COMPILE AND FLASH YOUR FIRST FIRMWARE. 10. CHIPS USED .... If your laptop already has a RS232 port, then you can ... download your own forked repository from github to your local computer. Detailed ...