High Performance, Configurable Data Acquisition System for Research & Development Testing gas turbines means dealing with a complex set of challenging environmental conditions. Sensors collect data on pressure, strain , vibration, and temperature while interacting with the extremes of these conditions. The combination of Precision Filters, Inc. proven rotating machinery signal conditioning with National Instruments PXI digitizers and APEX DS control and analysis software results in a system ready to address the most challenging turbine test environments.

Precision Filters 28000 Signal Conditioning System • • • • • •

Choice of 2, 4, 8 or 16-slot chassis Mix and match programmable signal conditioning for rotating machinery Condition strain, dynamic strain, bridge, charge and others Compatible with high temperature strain and piezo-electric sensors Measure and report transducer excitation, loop resistance and leakage resistance Automated factory acceptance and go/no-go tests verify system performance

Precision Filters Signal Conditioners Supported by APEX DS Data Acquisition Software

Legend Voltage

Charge Dynamic Strain

IEPE

Bridge

PF-28144

PF-28118

PF-28304

PF-28458

4 Channels

8 Channels

4 Channels

8 Channels

AC

AC/DC

Bridge

Thermalcouple

National Instruments PXIe-1085 Data Acquisition System • • • • •

18-Slot PXI Express Chas­sis, 1 PXI Express system timing slot Wide variety of PXI/PXIe analog input cards suppor­­ting voltage, IEPE and strain signal condi­­tio­­ning Up to 8 GB/s per-slot dedi­ca­ted band­width, 24 GB/s system band­width 925 W total power for 0 to 55 °C Runs with APEX DS on external server PC via MXI interface

Industrial National Instruments Hardware Supported by APEX DS Data Acquisition Software

PXIe-4353 32 Channels

PXIe-4331 8 Channels

PXIe-4462 4 Channels

PXIe-4464 4 Channels

PXIe-4492 8 Channels

Legend

PXIe-4495 16 Channels

Best Selling

Voltage Dynamic Strain

PXIe-4496 16 Channels

IEPE

PXIe-4497 16 Channels

Microphone

AC

AC/DC

PXIe-4498 16 Channels

W W W. P F I N C . C O M | W W W. N I . C O M | W W W. A P E X T U R B I N E . C O M

PXIe-4499 16 Channels

Designed to handle hundreds of clients connected to multiple data acquisition servers.

Test Operations Panel 64 Channels Shown

Double-Click plot for full screen view with spectrum

Visual Signal Health Monitoring Check signal health in an instant. Signal health is presented in red/yellow/green. Over Range

Near Over Range

Continuous Monitor Mode Recording and Event Recording •

Best in indus­try real-time moni­to­ring on a variety of engi­nee­ring diagrams inclu­ding: Time, Digi­tal O-scope, Camp­bell, Z-mod, EO Tracking, Spec­trum/Enve­lope, Water­fall, Strip­chart, History and Margin



All new software architecture with advanced multithreading for increased performance and stability



Improved quality testing with full-scale test network and expanded testing procedures



FREE analysis file viewer for replay

“ Te s t a l l t h i n g s . Hold on to what is good.”

W W W. A P E X T U R B I N E . C O M

+1 931 486 0081

Industrial Signal Conditioning Hardware Sales Sheet-28000.pdf ...

Page 2 of 2. Industrial Signal Conditioning Hardware Sales Sheet-28000.pdf. Industrial Signal Conditioning Hardware Sales Sheet-28000.pdf. Open. Extract.

2MB Sizes 4 Downloads 175 Views

Recommend Documents

Industrial Signal Conditioning Hardware Sales Sheet-28000.pdf ...
National Instruments PXIe-1085 Data Acquisition System. • 18-Slot PXI Express Chassis, 1 PXI Express system timing slot. • Wide variety of PXI/PXIe analog ...

Industrial Hardware Sales Sheet-WX-7000.pdf
There was a problem previewing this document. Retrying... Download. Connect more apps... Try one of the apps below to open or edit this item. Industrial ...

Industrial Hardware Sales Sheet-PCI Server System.pdf ...
Page 2 of 2. +1 931 486 0081. “Test all things. Hold on to what is good.” Designed to handle hundreds of clients. connected to multiple data acquisition. servers.

Sensor Signal Conditioning
tion voltage is shown in Figure 4.1.17. ... Figure 4.1.17: Driving remote bridge ...... PC, and laptop computer applications are demanding IC vendors to supply ...... lel for 1 inch have a leakage resistance of approximately 1011 ohms at +125°C. If.

Sensor Signal Conditioning
They are inexpensive to ..... are available on the Internet (http:// ...... cheap. Optical isolators are fast and cheap, and can be made with very high volt- age ratings ...

Industrial Training Final Report Hardware & Networking.pdf ...
Industrial Training Final Report Hardware & Networking.pdf. Industrial Training Final Report Hardware & Networking.pdf. Open. Extract. Open with. Sign In.

Highly-Portable Hardware Sales Sheet-CompactDAQ ...
Highly-Portable Hardware Sales Sheet-CompactDAQ & CompactRIO.pdf. Highly-Portable Hardware Sales Sheet-CompactDAQ & CompactRIO.pdf. Open.

Ultra-Portable Hardware Sales Sheet-cDAQ-9171.pdf
Over Range Near Over Range. Page 2 of 2. Ultra-Portable Hardware Sales Sheet-cDAQ-9171.pdf. Ultra-Portable Hardware Sales Sheet-cDAQ-9171.pdf. Open.

Air Conditioning Edmonton Links - Air Conditioning Edmonton.pdf ...
Page 1 of 6. Air Conditioning Edmonton — Quality Residential Heating and Cooling Installations & Repairs! Click here to learn more.. We adhere to a high set of standards when it comes to serving our customers. Honest, ethical business practices. 10

Hardware and Representation - GitHub
E.g. CPU can access rows in one module, hard disk / another CPU access row in ... (b) Data Bus: bidirectional, sends a word from CPU to main memory or.

Air Conditioning Service.pdf
to make sure you have the best comfort in your home. It doesn't matter what time it is, our team will have your home back to being comfortable in no time. We.

Junior Instructor -Mechanic Industrial Electronics - Industrial Training ...
(o 6A @) o.4A. lt. A wd biad ... @1l hs .n op.n voriase : (c) r.5v ... Displaying Junior Instructor -Mechanic Industrial Electronics - Industrial Training.pdf. Page 1 of ...

Air Conditioning Installation.pdf
When you buy a new air conditioning or heating unit to replace your old one -- or if a. completely new system is being installed in your new home -- the installer ...

Air Conditioning Edmonton.pdf
Get comfortable with AC residential systems. Life can be. unpredictable. So when you're home, your sense of comfort. and relaxation should be just how you want it to be. Air Conditioner Repairs & Replacements? Call 780-800-7010 or Visit. http://air-c

Air Conditioning Unit.pdf
Air Conditioning Installation. Home Air Conditioner. Heating And Air Conditioning. Central Air Unit. Heating And Cooling. Ductless Air Conditioner. Ac Repair. Air Conditioning Repair. Page 3 of 4. Air Conditioning Unit.pdf. Air Conditioning Unit.pdf.

Air Conditioning Installation.pdf
Air Conditioning Repair. HVAC Unit. New Air Conditioner. Air Con Units. Central Air Conditioner Prices. HVAC Companies. Air Conditioning System. Central Air Conditioning Unit. Air Conditioning Service. Home Ac Units. Page 3 of 4. Air Conditioning Ins

Air Conditioning Service.pdf
to make sure you have the best comfort in your home. It doesn't matter what time it is, our team will have your home back to being comfortable in no time. We.

JUNIOR INSTRUCTOR-MECHANIC COMPUTER HARDWARE ...
(D) Fo'tran. lia@ a trTe of network it which anv conputar can aci a! both a sefld! md cliont : ... A deqe rn rnddrs @mptrkr getrsar€d dds i' a form Nisble lo' rrtn'oissis rrmu3b ... COMPUTER HARDWARE-INDUSTRIAL TRAINING DEPARTMENT.pdf.

ICESCA'08_Nabil_chouba_Multilayer Neuronal network hardware ...
Abstract— Perceptron multilayer neuronal network is widely ... Index Terms— neuronal network, Perceptron multilayer, ..... Computers, C-26(7):681-687, 1977.

Computer Science 141 Computing Hardware
Examples: – 1951 UNIVAC — 5K adds/sec in a 4400 ft3 package (22' x 20' x 10'). – 2010 Nvidia GTX580 GPU — 1.58T FPadd/sec. And demand is keeping ...