Heat Pump GSM Remote Control (FD25/35)

Control your heat pump from anywhere. Easy to use. Access Code -protection to prevent unauthorized remote access. Easy access to most frequently used controls. A total of 12 remote controlled heat pump related functions/parameters. Preserves settings during a power outage.

Heat Pump GSM Remote Control (FD25/35)

Installation 1. Insert the SIM card to cell phone SIM card

(Note: cell phone and SIM card not included with GSM Remote Controller)

2. Plug in the charger and hands-free cables to phone

hands-free cable charger cable

3. Turn on the phone and enter your SIM card PIN code

Power on + insert PIN

4. Turn on the Mini-GSM controller

Heat Pump GSM Remote Control (FD25/35)

Installation (continues...)

5. Make sure the front panel of the GSM remote controller points toward the indoor unit.

6. Now your setup should look like this and you are ready to configure cell phone!

Heat Pump GSM Remote Control (FD25/35)

Installation (Configuring cell phone)

There are a few settings to set right in cell phone (in this case we are using Nokia 3120) before we can start remote controlling. 1. Make sure you have general profile in use. If you are unsure what profile you have in use, hit power button once and choose ”General”. 2. Go to ”Menu -> Profiles -> General -> Personalise” and make sure everything there is set as follows: Incoming call alert: Ringing Ringing tone: Croak Ringing volume: Level 1 (= min) Vibrating alert: Off Message alert tone: Off Keypad tones: Level 3 (= max) Warning tones: Off Rhythmic backlight alert: Off Alert for: All calls 3. Make sure you have handsfree cable attached to cell phone. 4. Go to ”Menu -> Settings -> Enhancement settings -> Headset” and make sure everything there is set as follows: Default profile: Current Profile Automatic answer: On 5. Make a call to cell phone attached to a GSM remote controller. When cell phone automatically answers to your call press its button until volume is set to max level. 6. Ready!

Heat Pump GSM Remote Control (FD25/35)

How to use?

1. Make a call to Mini-GSM remote control attached cell phone. Can I change or disable Access Code? No.

2. Cell phone attached to Mini-GSM remote control will answer to your call automatically.

I unlocked the remote controller using Access Code. How long it takes before it reactivates? Reactivation happens about 2 min after last button press.

3. Enter your remote controller Access Code and start controlling your heat pump.

Basic functions cooling automatic power on

heating

power off temperature up by 1C° temperature 22C° temperature down by 1C° other control commands

Heat Pump GSM Remote Control (FD25/35)

Heat pump related commands

Fan #00 = #01 = #02 = #03 = #04 =

Auto Low Medium High Super High

Vane #10 = #11 = #12 = #13 = #14 = #15 = #16 =

Auto 1 2 3 4 5 Swing

Widevane #20 = #21 = #22 = #23 = #24 = #25 = Swing Area #30 = #31 = #32 = #33 =

Auto Left Right Release/Cancel

EconoCool #40 = Off #41 = On Clean #50 = Off #51 = On Plasma #60 = Off #61 = On i-see #70 = Off #71 = On Installation Position #80 = Left #81 = Center #82 = Right

Heat Pump GSM Remote Control (FD25/35)

GSM remote controller related commands

What is Autosend? Default function of Mini GSM remote controller is to send IR control message to heat pump right after every command or control.

This function can be turned off so that only * button sends control message to heat pump.

I entered a command that is not on these lists. What happens

#90 = Reset GSM remote controller with following settings: Operation mode: Heating Fan speed: Super High Vane: Swing WideVane: Swing Area: Auto EconoCool: Off Clean: Off Plasma: Off i-see: Off Power: Off Temperature: 22 Installation position: Center GSM remote controller sound: On Autosend: On (Note: Resetting the GSM remote controller does not send any control messages to the heat pump)

now? If you have Autosend on, currently active settings are sent to heat pump.

When recovering from power outage, does the GSM remote controller automatically send commands to the heat pump? No. FD25/35 heat pump has ”Auto restart function”.

#95 = Autosend OFF #96 = Autosend ON #97 = GSM remote controller sound OFF #98 = GSM remote controller sound SHORTER VERSION #99 = GSM remote controller sound ON+RESET

Heat Pump GSM Remote Control (FD25/35)

Remote control example (step by step)

- Power: On - Operation mode: Heating - Temperature: 24 (1-2-6-3-3) In this example Autosend is assumed to be on.

Press 1 (power: on). You will hear multiple beeps to indicate that IR control is sent to heat pump.

If you have set Autosend off in your GSM controller, then button sequence would be (1-2-6-3-3-*)

Press 2 (operation mode: heating). You will hear multiple beeps to indicate that IR control is sent to heat pump.

Press 6 (temperature: 22C). You will hear multiple beeps to indicate that IR control is sent to heat pump.

Press 3 (temperature: +1C). You will hear multiple beeps to indicate that IR control is sent to heat pump. Press 3 again to increase temperature by 1C. You will hear multiple beeps to indicate that IR control is sent to heat pump.

Heat Pump GSM Remote Control (FD25/35)

Remote control examples

- Power: On - Operation mode: Heating - Temperature: 24 (1-2-6-3-3)

- Power: On - Operation mode: Cooling - Temperature: 21 (1-8-6-9)

- Power: On - Operation mode: Automatic - Temperature: 22 (1-5-6)

- Power: Off (4)

- Fan: Super High (#-0-4)

- Reset GSM remote controller (#-9-0)

In this example Autosend is assumed to be on.

If you have set Autosend off in your GSM controller, then you need to add * to end of every button sequence.

Heat Pump GSM Remote Control (FD25/35)

GSM Remote Controller front & rear panel

Infra-red signal transmitter

Indicators

GSM hf cord

GSM button press Controller unlocked Power on

Power cord

Heat Pump GSM Remote Control

Control your heat pump from anywhere. Easy to use. Access Code -protection to prevent unauthorized remote access. Easy access to most frequently used controls. A total of 12 remote controlled heat pump related functions/parameters. Preserves settings during a power outage.

777KB Sizes 13 Downloads 294 Views

Recommend Documents

Heat pump type brochure.pdf
Download. Connect more apps... Try one of the apps below to open or edit this item. Heat pump type brochure.pdf. Heat pump type brochure.pdf. Open. Extract.

Computer programmable remote control
Apr 3, 2001 - 180 (preferably a hard disk) as knoWn in the art. The general ..... commands against those of the screen objects in the data base. If a match is ...

Cheap Wireless Bluetooth Remote Control Multimedia Remote ...
Cheap Wireless Bluetooth Remote Control Multimedia Remote Music Control Camera Shutter for Smartphone.pdf. Cheap Wireless Bluetooth Remote Control ...

Computer programmable remote control
Apr 3, 2001 - development software and used to prepare a screen object corresponding to the programmed remote control unit 200A of the multimedia ...

Development of a Ground-Source Heat Pump System ...
lieating 1,800 kcal/h. Wnit-hmir mdcr. Oeothennal heat pump ..... ofthe Sth Inter- national Energy Agency. Heat Pump Conference 2005, pp. 4-8. 566. ASHRAE ...

GSM Based Remote Energy Meter Monitoring USING ...
RASPBERRY-PI is a credit card size minicomputer developed in UK. It acts as a fast processor system. ... does, like spreadsheets, word processing and games. .... [2]Mahesh Chahare , P.T.Karule, “ Wireless Electric Meter Reading Based On ...

Cheap 2017 S272 Gsm 3G M2M Remote Terminal Unit Quadband ...
Cheap 2017 S272 Gsm 3G M2M Remote Terminal Unit Q ... ilt In Gsm Gprs Module 12V-1.5A Free Shipping.pdf. Cheap 2017 S272 Gsm 3G M2M Remote ...

Remote Control Cars.pdf
remote control car. radio controlled cars. remote control trucks. rc drift. rc trucks for sale. traxxas rc. nitro rc. remote control cars for adults. fast remote control cars. rc buggy. rc monster truck. Recommended Links: https://goo.gl/Bd9Y7C. http

man-16\pentair-heat-pump-problems.pdf
man-16\pentair-heat-pump-problems.pdf. man-16\pentair-heat-pump-problems.pdf. Open. Extract. Open with. Sign In. Main menu.

man-62\heat-pump-preventive-maintenance.pdf
man-62\heat-pump-preventive-maintenance.pdf. man-62\heat-pump-preventive-maintenance.pdf. Open. Extract. Open with. Sign In. Main menu.

Development of a Ground-Source Heat Pump System ...
Development of a Ground-Source ... Yoshiro Shiba is a deputy manager ofthe Development Department, ... In the case of the application of 1.5 m cast-in-place.

mechatronics/process control remote laboratory
Advances in communication and information technology are reshaping our society in ... many engineering graduates follow diverse career paths in medicine, ...

RAILDOCs051-07 Remote Control Locomotive Operations Results ...
April 2005. Remote Control Locomotive .... Control Operators in the U.S. and Canada 2005.pdf ... Control Operators in the U.S. and Canada 2005.pdf. Open.

free download mobilewitch bluetooth remote control software ...
There was a problem previewing this document. Retrying... Download. Connect more apps... Try one of the apps below to open or edit this item. free download ...

NORCONTROL manual part1 ( Automation Remote Control System ...
NORCONTROL manual part1 ( Automation Remote Control System. Part.1 .Eng. ).pdf. NORCONTROL manual part1 ( Automation Remote Control System.

MIDNITE MNBIRDHOUSE1-RED Remote Combiner Disc Control ...
MIDNITE MNBIRDHOUSE1-RED Remote Combiner Disc Control Switch Datasheet.pdf. MIDNITE MNBIRDHOUSE1-RED Remote Combiner Disc Control ...

PUMP, PUMP AND AWAY -
Come with some innovative design of model rocket which use water as its reaction mass. (called water rocket) and defy the laws of gravity to keep your rocket in ...

remote comand system four residential domótica by gsm-sms - aedie
SMS is a globally accepted wireless service that enables the transmission of ... inputs to which external alarm systems are connected and outputs through which ... The use of a modem has advantages in terms of data handling and the use of ...

Pump construction
References Cited by the Examiner. The following references, cited by the Examiner, are of record in the patented ñle of this patent or the original patent. 10. 15. 8.

GSM - NSE
Jun 21, 2017 - Sub: Graded Surveillance Measure (GSM) – Updated list of companies ... SN Company Name ... Software Technology Group International.