Camur II FixVolt 1 Power supply for Cathodic Protection Description Camur II FixVolt 1​ ​is a power supply for cathodic protection of steel in concrete. Camur II FixVolt 1 is supplied with a safety transformer. Technical data Input Voltage (+Anode & -Steel) Current (+Anode & -Steel) Sampling interval: 1 s

0-10 V 0-200 mA

resolution 1 mV resolution 1 mA

Output Range

1 (constant current or constant voltage mode) 0,1 to 10 V DC (in 1 mV steps) 1 A at 0,1 to 5 V (in 1 mA steps) 0.5 A at 5 to 10 V (in 1 mA steps) Accuracy 0,5 % Temp. coefficient 0,005 % ​/​°C Ripple max 50 mV Power supply 24 V AC/DC (4 - 400 mA) Output turns off if temp exceeds 60 °C Dimensions (WxHxD) 70 x 83 x 34 mm - w/connectors and clip 92 x 92 x 40 Weight node w/connectors 140 g Delivered with DIN-rail mounting clip Connectors Bus Via left and right side quick plug bus connector (must be ordered separately). (+, - , H , L)

HS export code: 8504 4010 FixVolt 1, Rev 1 - May 2015 Page 1 of 2

Inputs / outputs Quick plug connector 24 V AC supply voltage from transformer

​+

Anode

brown/red cable

-

Steel

black cable

Measuring modes The FixVolt 1 node supports Camur II software Monitor with recording types active in modes: Monitor, Monitor Extended and Decay*. * only for channel U and I

HS export code: 8504 4010 FixVolt 1, Rev 1 - May 2015 Page 2 of 2

Camur II FixVolt 1

supplied with a safety transformer. Technical data. Input ... The FixVolt 1 node supports Camur II software Monitor with recording types active in modes: Monitor ...

205KB Sizes 0 Downloads 274 Views

Recommend Documents

Camur II FixVolt 3
Fuse 7.5 A (Blade type, brown mini fuse, vehicle type). Output turns off ... software. Note! Cables to sense must be used only for sense purpose. The sense point ...

Camur II Alarm
For monitoring and alarm triggering. Description. The Camur ... In Camur II software you select the alarm source and set the digital outputs on and off. Technical ...

Camur II LPR
Description. In addition to recording ​electric potential and ​LPR measurements, this node has an integrated semiconductor sensor for measuring temperature. ​The input channels are galvanically separated from the. Camur II Bus. Technical data.

Camur II P Quick
The P Quick node supports recording types Monitor, Monitor Extended and Decay in Camur II software. HS export code: 9031 8090. Camur II P Quick, Rev 1 ...

Camur II CrackWatch
Description. The Camur II CrackWatch in combination with a potentiometric sensor is perfect for monitoring changes in crack width. It is reading the voltage drop over the sensor, which is converted into length displacement in the Camur II software. C

Camur II CorroWatch
Technical data. Inputs. Voltage. 6. Current. 6 ... software. HS export code: 9031 8090. Camur II CorroWatch, Rev 1 - May 2015. Page 2 of 5 ... Current between A6 and CE. R 1 k Ω. Resistance between A1 and A2. R 2 k Ω. Resistance between ...

Camur II Controller software
Camur II Controller software. Camur II Monitor and Camur II Server, software running on the Camur II Controller. Description. Camur II Server (Controller).

Camur II MRE
Unit. Measurement. R1. kΩ resistance between R1 - R2. R2. kΩ resistance between R2 - R3. R3. kΩ resistance between R3 - R4. R4. kΩ resistance between R4 - R5. R5. kΩ resistance between R5 - R6. R6. kΩ resistance between R6 - R7. R7. kΩ resista

Camur II P4 Quick
The P4 Quick node is made for monitoring of electrochemical reference electrodes ... recording types Monitor, Monitor Extended and Decay in Camur II software.

Camur II Project Manager
operators' laptops, office servers etc. Remote monitoring via Project Manager lets you access all settings and data on the Camur II Controller, so you may ...

Camur II Web Console
Installation manual is available at ​http://camur-ii.protector.no/manuals​. Software and hardware requirements (desktop application). A recently updated web ...

Camur II Bus Repeater
Description. The Camur II Bus Repeater can be installed anywhere on the Camur II. Bus to create a new, galvanically isolated, bus segment (labelled "bus 2" below). This allows the Camur II Bus to be branched and capacity to be extended by another 100

Camur II CM-2
essential feature compared to the use of a Digital Multi Meter, DMM which can be unreliable. Cable resistance if long cables are used can be eliminated with the CM-2s calibration feature. The CM-2 tester is delivered as a briefcase complete with char

Camur II P+T
The P+T node is made for monitoring of electrochemical reference electrodes (RE) ... recording types Monitor, Monitor Extended and Decay in Camur II software.

Camur II Anode Ladder Quick
Technical data. Inputs. Voltage. 7. Current ... software. Outputs from measurements in standard format reports a list of the measurements of each sensor in the ... Resistance between A6 and RC. R 7 k​Ω. Resistance between RC and C. T. °​C.

Camur II Ethernet Interface
80 mA @ 12 V (from bus). Max no. of nodes. 100. Weight node w/connectors. 130 g. Power supply (included). 24 V / 2.5 A. Dimensions (WxHxD). 68 x 81 x 34 mm. - w/connectors and clip. 80 x 132 x 40 ... 10 seconds to reset to static IP address (default

Camur II ZRA ​(Zero Resistance Amperemeter)
range selection for accurate measurements. ​The input channel is galvanically separated from the Camur II. Bus. Technical data. Inputs. 1. Input range (max). ± 2 mA. Temp. coefficient. 0.01 % / ​°C ... It can be either zero, like during the mea

Camur II Control Cabinet for Cathodic Protection ...
The cabinets are based on multi-mount mild steel cabinets from Eldon's MAS (single door) and MAD. (double door) series. RAL color 7032. Stainless steel ARS cabinets can be made on request. General cabinet sizes are as follows. Measures H x W x D. Rec

j; 2, 1' Ii
Jun 13, 2006 - ABSTRACT. An EEPROM having a memory cell array in Which electri .... 2 F535:;2.i3 wzo mom. 2. Q m 0. N o' o'. THRESHOLD VOLTAGE ob.

Accountancy-II 1.pdf
2 to 5 (of which two will be of numerical nature and other two of theoretical nature) will. carry 2 marks each. Answer of each theoretical question should be given ...

RELATIONAL MODEL-II.1.pdf
Database Schema and Database Instance. Design of a database is called the schema. Schema is of three types: Physical schema,. logical schema and view ...

hospital administration - ii (1).pdf
Download. Connect more apps... Try one of the apps below to open or edit this item. hospital administration - ii (1).pdf. hospital administration - ii (1).pdf. Open.

Accountancy-II 1.pdf
Part from Part I and Part II. 3. All Questions will be compulsory. 4. 11 Questions will be set in the Question Paper. 5. All Units of the syllabus should be given adequate representation in the Question Paper. 6. There is no length limit for numerica

102 II. [1 [IIU'II' 100
tion of image data and ultimately may lead to some distor tion of the scanned image. To resolve the driving problem, sensors are often installed inside a ...