Camur​ ​II​ ​Anode​ ​Ladder​ ​Quick

For​ ​automatic​ ​monitoring​ ​of​ ​Anode​ ​Ladder1​ ​and​ ​Drill​ ​Core​ ​Anode​1​​ ​sensors Description The​ ​Camur​ ​II​ ​Anode​ ​Ladder​ ​node​ ​monitors​ ​automatically​ ​LPR,​ ​ZRA,​ ​resistance,​ ​potential​ ​and temperature.​ ​The​ ​inputs​ ​are​ ​galvanically​ ​separated​ ​from​ ​the​ ​bus​ ​side. Technical​ ​data Inputs Voltage Current AC​ ​resistance Temperature Temp.​ ​coefficient Noise Impedance Sampling​ ​interval

7 7 7 1​ ​(Pt1000) 0,009​ ​%​ ​/​ ​°C ±​ ​1​ ​division >​ ​50​ ​MΩ ≥​​ ​1​ ​s

Polarization​ ​output​ ​(LPR) Range ±​ ​2.4​ ​V Resolution 0.1​ ​mV Accuracy 0.009​ ​% Resistance​ ​measurement​ ​signals Vosc Rout Range​ ​1 1​ ​V 220​ ​Ω​ ​(below​ ​500​ ​Ω:​ ​0.5​ ​V​ ​/​ ​220​ ​Ω​) Range​ ​2 1​ ​V 220​ ​Ω Range​ ​3 1​ ​V 220​ ​Ω Range​ ​4 1​ ​V 220​ ​Ω Frequency​ ​of​ ​1kHz Power​ ​in Power​ ​consumption Dimensions​ ​(WxHxD) Weight

1

12-48​ ​VDC 18​ ​mA​ ​@​ ​24​ ​V 64​ ​x​ ​82​ ​x​ ​34​ ​mm 125​ ​g

​ ​Sensortec​ ​GmbH

HS​ ​export​ ​code:​ ​9031​ ​8090

Camur​ ​II​ ​Anode​ ​Ladder,​ ​Rev​ ​1​ ​-​ ​May​ ​2015 Page​ ​1​ ​of​ ​5

Range​ ​1 Resolution Accuracy

Voltage ±​ ​2.4 VDC 0.1 mV 0.2 mV

Current ±​ ​5 mADC 1 μA 1 μA

AC​ ​resistance 1​ ​-​ ​2000 Ω 1 Ω 1 %

Range​ ​2 Resolution Accuracy

-

±​ ​400 μA 0.05 μA 0.1 μA

2-20 1 1

k​Ω Ω %

-

Range​ ​3 Resolution Accuracy

-

±​ ​40 0.01 0.05

20​ ​-​ ​100 10 1

k​Ω Ω %

-

Range​ ​4 Resolution Accuracy

-

-

μA μA μA

0.1​ ​-​ ​3 M​Ω 100 Ω 10 % (5%​ ​below​ ​1​ ​MΩ)

Temperature -50​ ​-​ ​+100​°C 0.01​ ​°C ±​ ​0.1​ ​°C

-

Connectors Bus Double​ ​set​ ​of​ ​screw​ ​terminals​ ​in​ ​the​ ​node​ ​box. (+,​ ​-​ ​,​ ​H​ ​,​ ​L) Input​ ​/​ ​output A1​ ​-​ ​A6 Anodes​ ​(working​ ​electrodes)​ ​1​ ​-​ ​6 RC Rebar​ ​connection C Cathode​ ​(counter​ ​electrode) RE Reference​ ​electrode P1+ Supply​ ​voltage​ ​for​ ​Pt1000 P2Supply​ ​voltage​ ​for​ ​Pt1000 P1 Input​ ​for​ ​Pt1000 P2 Input​ ​for​ ​Pt1000 Note! For​ ​two-wire​ ​Pt1000​ ​sensors,​ ​connect​ ​P1+​ ​with​ ​P1​ ​and​ ​P2-​ ​with​ ​P2. The​ ​analog​ ​inputs​ ​are​ ​not​ ​galvanically​ ​separated​ ​from​ ​each​ ​other. Recording​ ​types HS​ ​export​ ​code:​ ​9031​ ​8090

Camur​ ​II​ ​Anode​ ​Ladder,​ ​Rev​ ​1​ ​-​ ​May​ ​2015 Page​ ​2​ ​of​ ​5

The​ ​Anode​ ​Ladder​ ​node​ ​supports​ ​recording​ ​types​ ​Monitor,​ ​Monitor​ ​Extended​ ​and​ ​LPR​ ​in​ ​Camur​ ​II software. Outputs​ ​from​ ​measurements​ ​in​ ​standard​ ​format​ ​reports​ ​a​ ​list​ ​of​ ​the​ ​measurements​ ​of​ ​each​ ​sensor​ ​in​ ​the format:​ ​[sensor​ ​name]-[value​ ​type],​ ​one​ ​column​ ​for​ ​each​ ​combination.​ ​Measurements​ ​that​ ​belong​ ​to​ ​the same​ ​sample​ ​interval​ ​are​ ​collected​ ​in​ ​one​ ​row. Measurement​ ​reports Monitor Value​ ​/​ ​type

Unit

Measurement

I​ ​1

mA

Current​ ​between​ ​A1​ ​and​ ​C

I​ ​2

mA

Current​ ​between​ ​A2​ ​and​ ​C

I​ ​3

mA

Current​ ​between​ ​A3​ ​and​ ​C

I​ ​4

mA

Current​ ​between​ ​A4​ ​and​ ​C

I​ ​5

mA

Current​ ​between​ ​A5​ ​and​ ​C

I​ ​6

mA

Current​ ​between​ ​A6​ ​and​ ​C

I​ ​7

mA

Current​ ​between​ ​RC​ ​and​ ​C

R​ ​1

k​​ ​Ω

Resistance​ ​between​ ​A1​ ​and​ ​A2

R​ ​2

k​​ ​Ω

Resistance​ ​between​ ​A2​ ​and​ ​A3

R​ ​3

k​​ ​Ω

Resistance​ ​between​ ​A3​ ​and​ ​A4

R​ ​4

k​​ ​Ω

Resistance​ ​between​ ​A4​ ​and​ ​A5

R​ ​5

k​​ ​Ω

Resistance​ ​between​ ​A5​ ​and​ ​A6

R​ ​6

k​​ ​Ω

Resistance​ ​between​ ​A6​ ​and​ ​RC

R​ ​7

k​​ ​Ω

Resistance​ ​between​ ​RC​ ​and​ ​C

T

°​C

Temperature

U​ ​1

mV

Potential​ ​between​ ​A1​ ​and​ ​RE

U​ ​2

mV

Potential​ ​between​ ​A2​ ​and​ ​RE

U​ ​3

mV

Potential​ ​between​ ​A3​ ​and​ ​RE

U​ ​4

mV

Potential​ ​between​ ​A4​ ​and​ ​RE

U​ ​5

mV

Potential​ ​between​ ​A5​ ​and​ ​RE

HS​ ​export​ ​code:​ ​9031​ ​8090

Camur​ ​II​ ​Anode​ ​Ladder,​ ​Rev​ ​1​ ​-​ ​May​ ​2015 Page​ ​3​ ​of​ ​5

U​ ​6

mV

Potential​ ​between​ ​A6​ ​and​ ​RE

U​ ​7

mV

Potential​ ​between​ ​RC​ ​and​ ​RE

Monitor​ ​Extended The​ ​same​ ​as​ ​in​ ​Monitor​ ​plus​ ​LPR​ ​result​ ​calculation Value/ type

Unit

Measurement

C1​ ​I

mA

Calculated​ ​corrosion​ ​current​ ​at​ ​A1

C2​ ​I

mA

Calculated​ ​corrosion​ ​current​ ​at​ ​A2

C3​ ​I

mA

Calculated​ ​corrosion​ ​current​ ​at​ ​A3

C4​ ​I

mA

Calculated​ ​corrosion​ ​current​ ​at​ ​A4

C5​ ​I

mA

Calculated​ ​corrosion​ ​current​ ​at​ ​A5

C6​ ​I

mA

Calculated​ ​corrosion​ ​current​ ​at​ ​A6

C7​ ​I

mA

Calculated​ ​corrosion​ ​current​ ​at​ ​RC

LPR​ ​measurements C1-V

mV

Potential​ ​between​ ​A1​ ​and​ ​RE

C1-I

mA

Current​ ​between​ ​A1​ ​and​ ​C

C2-V

mV

Potential​ ​between​ ​A2​ ​and​ ​RE

C2-I

mA

Current​ ​between​ ​A2​ ​and​ ​C

C3-V

mV

Potential​ ​between​ ​A3​ ​and​ ​RE

C3-I

mA

Current​ ​between​ ​A3​ ​and​ ​C

C4-V

mV

Potential​ ​between​ ​A4​ ​and​ ​RE

C4-I

mA

Current​ ​between​ ​A4​ ​and​ ​C

C5-V

mV

Potential​ ​between​ ​A5​ ​and​ ​RE

C5-I

mA

Current​ ​between​ ​A5​ ​and​ ​C

C6-V

mV

Potential​ ​between​ ​A6​ ​and​ ​RE

C6-I

mA

Current​ ​between​ ​A6​ ​and​ ​C

HS​ ​export​ ​code:​ ​9031​ ​8090

Camur​ ​II​ ​Anode​ ​Ladder,​ ​Rev​ ​1​ ​-​ ​May​ ​2015 Page​ ​4​ ​of​ ​5

C7-V

mV

Potential​ ​between​ ​RC​ ​and​ ​RE

C7-I

mA

Current​ ​between​ ​RC​ ​and​ ​C

LPR​ ​results Value/ type

Unit

Measurement

C1I

mA

Calculated​ ​corrosion​ ​current​ ​at​ ​A1

C1S

mA

Standard​ ​deviation​ ​for​ ​corrosion​ ​current​ ​at​ ​A1

C2I

mA

Calculated​ ​corrosion​ ​current​ ​at​ ​A2

C2S

mA

Standard​ ​deviation​ ​for​ ​corrosion​ ​current​ ​at​ ​A2

C3I

mA

Calculated​ ​corrosion​ ​current​ ​at​ ​A3

C3S

mA

Standard​ ​deviation​ ​for​ ​corrosion​ ​current​ ​at​ ​A3

C4I

mA

Calculated​ ​corrosion​ ​current​ ​at​ ​A4

C4S

mA

Standard​ ​deviation​ ​for​ ​corrosion​ ​current​ ​at​ ​A4

C5I

mA

Calculated​ ​corrosion​ ​current​ ​at​ ​A5

C5S

mA

Standard​ ​deviation​ ​for​ ​corrosion​ ​current​ ​at​ ​A5

C6I

mA

Calculated​ ​corrosion​ ​current​ ​at​ ​A6

C6S

mA

Standard​ ​deviation​ ​for​ ​corrosion​ ​current​ ​at​ ​A6

C7I

mA

Calculated​ ​corrosion​ ​current​ ​at​ ​RC

C7S

mA

Standard​ ​deviation​ ​for​ ​corrosion​ ​current​ ​at​ ​RC

HS​ ​export​ ​code:​ ​9031​ ​8090

Camur​ ​II​ ​Anode​ ​Ladder,​ ​Rev​ ​1​ ​-​ ​May​ ​2015 Page​ ​5​ ​of​ ​5

Camur II Anode Ladder Quick

Technical data. Inputs. Voltage. 7. Current ... software. Outputs from measurements in standard format reports a list of the measurements of each sensor in the ... Resistance between A6 and RC. R 7 k​Ω. Resistance between RC and C. T. °​C.

214KB Sizes 2 Downloads 315 Views

Recommend Documents

Camur II P Quick
The P Quick node supports recording types Monitor, Monitor Extended and Decay in Camur II software. HS export code: 9031 8090. Camur II P Quick, Rev 1 ...

Camur II P4 Quick
The P4 Quick node is made for monitoring of electrochemical reference electrodes ... recording types Monitor, Monitor Extended and Decay in Camur II software.

Camur II FixVolt 1
supplied with a safety transformer. Technical data. Input ... The FixVolt 1 node supports Camur II software Monitor with recording types active in modes: Monitor ...

Camur II Alarm
For monitoring and alarm triggering. Description. The Camur ... In Camur II software you select the alarm source and set the digital outputs on and off. Technical ...

Camur II LPR
Description. In addition to recording ​electric potential and ​LPR measurements, this node has an integrated semiconductor sensor for measuring temperature. ​The input channels are galvanically separated from the. Camur II Bus. Technical data.

Camur II CrackWatch
Description. The Camur II CrackWatch in combination with a potentiometric sensor is perfect for monitoring changes in crack width. It is reading the voltage drop over the sensor, which is converted into length displacement in the Camur II software. C

Camur II CorroWatch
Technical data. Inputs. Voltage. 6. Current. 6 ... software. HS export code: 9031 8090. Camur II CorroWatch, Rev 1 - May 2015. Page 2 of 5 ... Current between A6 and CE. R 1 k Ω. Resistance between A1 and A2. R 2 k Ω. Resistance between ...

Camur II FixVolt 3
Fuse 7.5 A (Blade type, brown mini fuse, vehicle type). Output turns off ... software. Note! Cables to sense must be used only for sense purpose. The sense point ...

Camur II Controller software
Camur II Controller software. Camur II Monitor and Camur II Server, software running on the Camur II Controller. Description. Camur II Server (Controller).

Camur II MRE
Unit. Measurement. R1. kΩ resistance between R1 - R2. R2. kΩ resistance between R2 - R3. R3. kΩ resistance between R3 - R4. R4. kΩ resistance between R4 - R5. R5. kΩ resistance between R5 - R6. R6. kΩ resistance between R6 - R7. R7. kΩ resista

Camur II Project Manager
operators' laptops, office servers etc. Remote monitoring via Project Manager lets you access all settings and data on the Camur II Controller, so you may ...

Camur II Web Console
Installation manual is available at ​http://camur-ii.protector.no/manuals​. Software and hardware requirements (desktop application). A recently updated web ...

Camur II Bus Repeater
Description. The Camur II Bus Repeater can be installed anywhere on the Camur II. Bus to create a new, galvanically isolated, bus segment (labelled "bus 2" below). This allows the Camur II Bus to be branched and capacity to be extended by another 100

Camur II CM-2
essential feature compared to the use of a Digital Multi Meter, DMM which can be unreliable. Cable resistance if long cables are used can be eliminated with the CM-2s calibration feature. The CM-2 tester is delivered as a briefcase complete with char

Camur II P+T
The P+T node is made for monitoring of electrochemical reference electrodes (RE) ... recording types Monitor, Monitor Extended and Decay in Camur II software.

Camur II Ethernet Interface
80 mA @ 12 V (from bus). Max no. of nodes. 100. Weight node w/connectors. 130 g. Power supply (included). 24 V / 2.5 A. Dimensions (WxHxD). 68 x 81 x 34 mm. - w/connectors and clip. 80 x 132 x 40 ... 10 seconds to reset to static IP address (default

Camur II ZRA ​(Zero Resistance Amperemeter)
range selection for accurate measurements. ​The input channel is galvanically separated from the Camur II. Bus. Technical data. Inputs. 1. Input range (max). ± 2 mA. Temp. coefficient. 0.01 % / ​°C ... It can be either zero, like during the mea

Camur II Control Cabinet for Cathodic Protection ...
The cabinets are based on multi-mount mild steel cabinets from Eldon's MAS (single door) and MAD. (double door) series. RAL color 7032. Stainless steel ARS cabinets can be made on request. General cabinet sizes are as follows. Measures H x W x D. Rec

ZEBRA Anode
application of AHEAD Multiprimer and wearing courses. If not, the resistivity will be too high, and the ... of proper ventilation during the installation. Technical data.

Ladder epochs and law of the maximum of ladder ...
Summary. Let (Sn)n≥0 be a random walk on R; under quite large assumptions on its law µ we describe its oscillations and study several ways to condition it to stay nonnegative. Namely, we can first consider the condition that Sk ≥ 0 up to time n

Snakes and Ladder HFW FREEBIE.pdf
... a snake's head, they must slide down the snake to the number its tail. touches. Play continues until a player reaches the winner square. Note: The arrows help ...

plc ladder logic pdf
File: Plc ladder logic pdf. Download now. Click here if your download doesn't start automatically. Page 1 of 1. plc ladder logic pdf. plc ladder logic pdf. Open.