HALO SERIES UNDERGROUND LIGHTING SOLUTIONS IP68 Code HALO-UL-60
Lumen per LED’s per Power per Range fed from Min. Cutting meter meter meter both sides 36V Length
Applications
HALO-UL-36 Applications
HALO-UL-30 HALO-UL-24 Applications
HALO-UL-18 Applications
HALO-UL-12 Applications
Accessories Code HALO-UL-CC HALO-UL-ACH HALO-UL-CC
HALO-UL-RK
HALO-UL-RK HALO-UL-ACH
1000lm 183mm (11LED's) 9W 35m 60 Its versatility provides daylight conditions underground, ideal for haulages, refuge bays, conveyors and tipping areas 600lm 55m 306mm (11LED's) 36 5.5W Ideal where high bright conditions are required, commonly used at machine stations of conveyors 367mm (11LED's) 500lm 65m 30 4.4W Medium to high bright option, ideal for haulages and general tunnel lighting
300lm 75m 458mm (11LED's) 24 3.6W Providing a medium to good lighting platform, a good solution to run along conveyor belts 250lm 105m 18 3.3W 500mm (9LED's) Good luminescence, long range and high energy efficiency. Ideal lighting platform for stopes and confined spaces 200lm 155m 250mm (3LED's) 12 2.4W Medium to good lighting solution, with a long range and low consumption, ideal for stope areas and confined spaces
Description
Connector Kit: L-connector, T-connector, 5x anti-skid clips, 5x PC cover, 5x heat shrink tube
Repair Kit: front connector, 3m lead & end cap 1m Length profile & 5x fixing screws
Industrial Strip Lighting Accessories - Individual Components IP65
Code
Description
F17A-SFC-01 F17A-SFC-02 Sleeve Front Connector
Sleeve End Connector
F17A-SMC
Sleeve Middle Connector
F17A-SEC
F17A-SJ
Sleeve End Cap Sleeve Jumper 1
Sleeve Front Connector
Sleeve End Connector
Sleeve Middle Connector
Sleeve End Cap
F17A-PTF
Power T-Feed
2
3
F17A-C
F17A-GLUE
Clips 4
Sealing Glue
5
6
7
Power Supplies - Input 85-265VAC; Output: 36VDC
HALO-PC
HALO-MC
MSD-CV-300W
1
Code HALO-PC-60 HALO-PC-80 HALO-PC-100 HALO-PC-150 HALO-PC-200 HALO-PC-240 HALO-PC-300 HALO-PC-350 MSD-CV-300W Enclosure HALO-MC
FLP
Description
60W Power Supply, Aluminium IP67 80W Power Supply, Aluminium IP67 100W Power Supply, Aluminium IP67 150W Power Supply, Aluminium IP67 200W Power Supply, Aluminium IP67 240W Power Supply, Aluminium IP67 300W Power Supply, Aluminium IP67 350W Power Supply, Aluminium IP67 300W Power Supply, Encapsulated IP67 Lockable vented metal enclosure for power controllers, complete with pre-drilled holes for cable entries
7
HALO SERIES UNDERGROUND LIGHTING SOLUTIONS IP68 Halo Series Evacuation Pulse System IP68 Lumen per LED’s per Code meter meter 14 80lm HALO-PS Applications
Power per Range fed from meter both sides 24VDC 1W
100m
• Operating on high sight impact and not sound
• Perfect for machine operators with excellent visibility in smoke filled or low light conditions • The Halo Series Evacuation Pulse System will:
- Prevent your work force from entering dangerous environments - Bring order
- Suppress panic and provide comfort in a stressed and dangerous environment.
Accessories Code HALO-PS-CR
Description
Pulsating controller & remote
For 24VDC Power Supplies see pages 81 - 82
HALO-PS-CR
EXPLOSION PROOF LIGHTING Mid-Power LED Light IP66
• Osram LED & high efficiency drivers
• Suitable for harsh and corrosive environments -40 to 55°C • Robust Aluminium enclosure and tempered glass • Group II Zone 1
Code
Supply
EX-KF120H4V4CH 180-277VAC EX-KF120H6V6CH 180-277VAC Ex d IIB T8 Gb 60°
60°
120°
120°
EX-KF150H4V4CH 180-277VAC EX-KF150H6V6CH 180-277VAC
Power Colour Temp. Lumen Beam Weight (kg) Size (mm) 120W
6000-7100K
11500lm 60°
13.5
426x410x187
150W
6000-7100K
14400lm 60°
13.5
426x410x187
120W 150W
Code
KHJ-03 KHJ-12 SB209333/M12 KHJ-11
Torches IP68
11500lm 120°
6000-7100K
KHJ-12
KHJ-03
Accessories
6000-7100K
14400lm 120°
13.5 13.5
426x410x187
KHJ-11
SB209333/M12
Description
426x410x187
Weight (kg) 0.4 2.26 0.26 0.38
Mounting Bracket Stanchion Bracket Pendant Mount Eye Bolt M12 Wire Guard
• Osram/Cree LED source • High strength Aluminium hard anodized to military spec. for extreme resistance to abrasion and corrosion • Tempered glass and advanced optics for use up to 200m • 3 Modes: High output, working output, flashing (5Hz) • Constant current ensures stability of brightness • Lithium batteries with built-in heat/failure protection, provides high power capacity and long life span • Anti-roll octagonal design • Group II Zone 1 Ex ib IIC T4 Gb
Code
Colour Temp. Lumen
KACF80GCH68
6000-7000K
143lm
Beam Bat. Life Span Weight (kg) Size (mm) Spot Flood High Working 10°
80°
≥ 9hrs
≥ 18hrs 0.19
Ø35x156
Battery Lifespan: 300 cycles. Charge time: 6hrs. Rated input voltage: 3.7V. Rated capacity: 2.2Ah Spot beam at high output: @ 1m, Ø = 0.1m 5700Lx @ 5m, Ø = 0.5m 245Lx @ 10m, Ø = 1m 0Lx
FLP
2
EXPLOSION PROOF LIGHTING LED High Power Multi Purpose Light IP66
Ex nR II T4 Gc
• Energy saving in strong Aluminium housing • Powerful, accurate, anti glare, shock and vibration resistant • Osram LED's and high efficiency drivers • Used for area lighting in warehouses and petrochem sites -40 to 55°C • Group II zone 2, Zone 22
Code 200W
80W
60°
60°
120°
120°
Ex d IIB T8 Gb
EX-KPLB80H4CH EX-KPLB120H4CH EX-KPLB160H4CH EX-KPLB200H4CH EX-KPLB240H4CH EX-KPLB80H6CH EX-KPLB120H6CH EX-KPLB160H6CH EX-KPLB200H6CH EX-KPLB240H6CH
Accessories Code
Supply
100-240VAC 100-240VAC 100-240VAC 100-240VAC 100-240VAC 100-240VAC 100-240VAC 100-240VAC 100-240VAC 100-240VAC
Power Colour Temp. Lumen Beam Weight (kg) Size (mm) 80W 120W 160W 200W 240W 80W 120W 160W 200W 240W
6000-7100K 6000-7100K 6000-7100K 6000-7100K 6000-7100K 6000-7100K 6000-7100K 6000-7100K 6000-7100K 6000-7100K
60° 60° 60° 60° 60° 120° 120° 120° 120° 120°
8700 12420 16560 20700 24800 8700 12420 16560 20700 24800
9 11 11 16 21 9 11 11 16 21
210x400x161 260x400x161 260x400x161 400x400x161 500x400x161 210x400x161 260x400x161 260x400x161 400x400x161 500x400x161
Description
Pipe Clamp KHJ-01 Stanchion Bracket KHJ-02-* KHJ-01 Pendant Mount Eye Bolt M10 SB209333/M10 *Add bracket size to code: 80 (80-160W), 200 (200W), 250 (250W)
KHJ-02
SB209333/M10
Robust Low Bay LED Lights IP66
• Osram LED's and high efficiency drivers • High impact resistant enclosure, ideal for marine and corrosive environments -40 to 55°C • For extremely corrosive, wet, dusty, hot and cold conditions • Group II Zone 1, 2
Rectangular Code
Supply
Accessories Code
Description
EX-KAF30CH
Ex d IIB T5/T6 Gb
100-240VAC
KHJ-09 KHJ-04 KHJ-05 SB209333/M10
Round Code
Power Colour Temp. Lumen Beam Weight (kg) Size (mm) 30W
6000-7100K
3000
120°
0.4 0.27 0.1 0.1
100-240VAC 100-240VAC
Accessories Code
KHJ-05
KHJ-04
Supply
EX-KGF30 EX-KGF60
SB209333/M10
Power Colour Temp. Lumen Beam Weight (kg) Size (mm) 30W 60W
6000-7100K 6000-7100K
2900 4500
60° 60°
Description
KHJ-09 KHJ-07 KHJ-08 SB209333/M10
KHJ-07
KHJ-09
5.5 5.5
0.4 0.4 0.3 0.1
KHJ-08
LED High Bay Explosionproof Light - Supply Voltage: 85 - 265VAC 120° Beam Angle Code
Luminous Efficiency
SEM-HG*-*
50W, 70W, 100W, 120W 100lm/W
Ø295 x 164H Size (mm) *Add colour to code: ● CW (Cool White) 5000-5500k, ● WW (Warm White) 2700-3000k
3
FLP
311x284x190 311x284x190
Weight (kg)
Mounting Bracket Stanchion Bracket Wire Guard Pendant Mount Eye Bolt - M10
*Add Watts to code:
480x180x62
Weight (kg)
Mounting Bracket Pipe Clamp Wire Guard Pendant Mount Eye Bolt M10
KHJ-09
4.7
SB209333/M10
EXPLOSION PROOF LIGHTING LED Area Lights with Protection Brackets - c/w LED (Size is Body of Lamp)
Ex II2G Ex d I/II B
LT-0300
ALT-0300-GD
Area Light 300mm
Size (mm) Ø x L
141.5 x 300
Watts 110/220V
Watts 12/24V
ALT-0600-GD
Area Light 600mm
141.5 x 600
56W
96W
ALT-1200-GD
Area Light 1200mm
141.5 x 1200
112W
192W
Code Light LT-0300*
Code Guard ALT-0300-GD
LT-0600* LT-1200*
Description
48W
* Add voltage to code: 12 (12/24VDC), 110 (110VAC), 220 (220VAC) • Order light & guard separately
Light & Guard Combined
Flood Light 230V IP66 - Lamps excluded Code High Watts Pressure Sodium Lamp 70W BAT53-HSE70G 100W BAT53-HSE100G 250W BAT53-HSE250G 400W BAT53-HSE400G Description 400W
28W
250W
70/100W
ATEX: Group II category 2G Ideal for IIA, IIB locations Suitable for Zone 1, 2 and 21, 22 locations Aluminium reflector IP66 Temperature Range: -25°C to +55°C
Code Metal Halide Lamp BAT53-HIE70G BAT53-HIE100G BAT53-HIE250G BAT53-HIE400G
Code Empty Fitting
Lamp Holder
–
E27
–
E40
– BAT53-EMPTY
Code
Watts
Lamp Type
BAD-A200X
200W
Incandescent or
BAD61-HSE70X BAD61-HSE100X
160W 20W 70W
100W
E40
Ex mark: Ex II 2G Ex de II BT3 Material: Die cast aluminium alloy outer shell High pressure anti static plastic sprayed Silicon rubber seal, high grade anodic
Bulkhead IP65 - Supply Voltage: 230VAC - Lamps excluded
(empty fitting for use with a variety of lamps)
E27
Lamp Holder
E27
Mercury Blended or Energy Saving CFL
High Pressure Sodium. c/w ballast & ignitor High Pressure Sodium. c/w ballast & ignitor
E27 E27
Description BAD-A200X
BAD61
ATEX: Group II2G Ex d II CT4 Ideal for IIA, IIB, IIC areas Suitable for Zone 1 and Zone 2 locations. (Certificate No. PTB 03 ATEX 1077)
Energy Saving Lighting IP65 - Supply Voltage: 230VAC. Lamps included. Suitable for ceiling mounting. Lamp Code Watts Lamp Type Holder 42W Energy Saving CFL E27 BAD81-42X 68W Energy Saving CFL E27 BAD81-68X Description
BAD81-42X
BAD81-68X
Atex: Group II Category 2G Ideal for IIA, IIB, IIC areas Suitable for zone 1, 2 and 21, 22 Ex mark: II 2G Ex d II CT4
Accessories Code Description 42W Spare lamp 81004 68W Spare lamp 81005
Induction Explosion Proof Lighting IP66 - Supply Voltage: 230VAC - Lamps included. Code
*Add Watts to Code Size (mm)
JM-04-001*
40W, 50W Ø265 x 240H
• High Corrosive & High Temperature Resistant • High Pressure Die-cast Polycarbonate Material • Aluminium Anti-Corrosion Surface Treatment
FLP
4
EXPLOSION PROOF LIGHTING Fluorescent 230V - IP66 (Certificate No. S-XPL/04547) ATEX: Group II category 2GD Ideal for IIA, IIB, IIC locations Suitable for Zone 1, 2 and 21, 22
Material: Polycarbonate diffuser Full plastic body Ex mark: Ex II 2G Exedq II CT4
Ballast for 2 x 36W
Ballast for 2 x 58W * NB Note: For LED Zone 2,21 & 22 - Led Fitting complete with LED Tubes
Accessories
Code (CFL) Size (mm) Code (CFL) * Code (LED) Ceiling Mount Watts L x W x D Emergency Ceiling Mount BAY51-Q18X1X 1 x 18W (2FT) 780 x 196 x 128 BAY51-Q18X1X-EMG BNY81-LED9X1X
Code
Description
5136011
Explosion-proof ballast for 1x36W or 2x36W
BAY51-Q18X2X 2 x 18W (2FT) 780 x 196 x 128 BAY51-Q18X2X-EMG BNY81-LED9X2X
5118004
Explosion proof ballast for 1x18W or 2x18W
BAY51-Q36X1X 1 x 36W (4FT) 1380 x 222 x 134 BAY51-Q36X1X-EMG BNY81-LED18X1X
BAY51-Q56-BAL Explosion proof ballast for 2x58W
BAY51-Q36X2X 2 x 36W (4FT) 1380 x 222 x 134 BAY51-Q36X2X-EMG BNY81-LED18X2X
5136004
36W Key for opening fitting
BAY51-Q56X2X 2 x 58W (5FT) 1672 x 196 x 115 BAY51-Q56X2X-EMG BNY81-LED28X2X
5118002
18W Key for opening fitting
(Lamps excluded.) See page 743 for spare lamps. Emergency duration 90min on one lamp. BAY51-LH
Fluorescent 230V IP65 - c/w Lamps
Description
Lamps included 6400k daylight Rechargeable. c/w wheels & 2 light levels selectable Ex mark: Ex de II C T6
ATEX: Group II category 2G Ideal for IIA, IIB, IIC locations suitable for Zone 1 and 2 Material: Aluminium body, glass lamp housing, stainless steel diffuser, carbon steel reflector Ex mark: Ex II 2G Ex d II C T6
Code - Ceiling Mount BAY51S-18X BAY51S-36X BAY51D-36X BAY51D-72X Hand Lights & Torches
Code Power Supply Battery life
Charging time Ex Mark Zone
IP-Rating Size
Spares
Spare Lamp Holder for 18W to 36W
Portable Explosion Proof Light IP65 - c/w Battery
Description
5
Key
Watts
• Toughened Glass • Cable not included
1 x 18W 1 x 36W 2 x 18W 2 x 36W
Size (mm) L x W x D
885 x 130 x 130 1470 x 130 x 130 865 x 225 x 140 1470 x 225 x 140
Code
BW3210
Lamp Power Battery Type Working Time Material - Head/Battery Box
30W 12Ah Sealed Lead acid High: 16hrs/Low: 36hrs Aluminium Alloy/Aluminium Alloy
c/w battery charger
c/w battery charger
BSX-60
BAD203
BAD201
≤100W (E27)
7.2V 2Ah Battery (incl.)
3.6V 1.8Ah Battery (incl.)
– –
≥10hrs
4.5-6hrs
≥10hrs 4.5hrs
Ex II 2G Ex de II CT4
Ex II 2G Ex ib II CT6
Ex II 2G Ex ib II CT6
IP65
IP68
IP66
Zones 1 & 2
Ø138 x 433mm
Spare Glass: BSX102
Zones 1 & 2
Ø40 x 208mm
Battery 203-BAT
FLP
Zones 1 & 2
Ø25 x 120mm
Battery 201-BAT
c/w battery charger
BAD303 6V 4.5Ah Battery (incl.)
High Intensity: 1-2hrs. Working light: ≥10hrs 12-16hrs
Ex II 2G Ex de II CT4 Zones 1 & 2 IP68
105 x 53 x 153 (excl. head) Battery 303-BAT
EX ED AT OV PR AP
EXPLOSION PROOF LIGHTING
Titano Asymmetrical Diffused Floodlights (wide beam) 230V IP66
Current
Lamp Type
Watts
Code GW84592M GW84594M GW84407
250W 400W Optional Wire Guard
Halle-High Bay GW83563S GW83564M GW83566S GW83567M GW84814
230V IP65 Control Gear. 470mm ø Bowl 250W SE High Pressure Sodium 250W ME Metal Halide 400W SE High Pressure Sodium 400W ME Metal Halide Optional Wire Guard
Lamp Holder
E40 MT Metal Halide 2.2A E40 MT Metal Halide 3.4A GW84592M - 250W 1kV II 3G - Ex nR IIA T2 Gc X II 3D - Ex tc IIIA T240°C Dc IP66 X -20°C ≤ Ta ≤ +25°C GW84594M - 400W 1Kv II 3G - Ex nR IIA T2 Gc X II 3D - Ex tc IIIA T240°C Dc IP66 X -20°C ≤ Ta ≤ +25°C E40 E40 E40 E40 -
3A 2.2A 4.2A 3.4A
GW83563S - 250W II3GD Ex nA IIC T2 Gc Ex tc IIIC T113°C Dc -20°C ≤ Ta ≤ +25°C X IP65 GW83564M - 250W 1kV II3GD Ex nA IIC T1 Gc Ex tc IIIC T137°C Dc -20°C ≤ Ta ≤ +25°C X IP65 GW83566S - 400W II3GD Ex nA IIC T1 Gc Ex tc IIIC T156°C Dc -20°C ≤ Ta ≤ +25°C X IP65 GW83567M - 400W 1kV II3GD Ex nA IIC T1 Gc Ex tc IIIC T137°C Dc -20°C ≤ Ta ≤ +25°C X IP65
IP65 - ATEX ZNT ZONE 2(G) - ZONE 22D Range - with P.F. correction - Class 1 RAL 7035 Grey shock resistant polycarbonate base, weatherproof light fitting (Lamps excluded) Spare Diffuser GW80134 GW80135 GW80136
Code GW81084 GW81085 GW81086
GW81084 Stainless steel diffuser clamps Spare Clamps GW88255
II 3 G – Ex nA IIB T4 Gc
Lamp Power
Dimensions (mm) L x H x W
No. of Lamps
(2ft) 680 x 112 x 195 (4ft) 1290 x 112 x 195 (5ft) 1590 x 112 x 195`
2 2 2
18W 36W 58W
GW81085
GW81086
II 3 G – Ex nA IIB T4 Gc
II 3 G – Ex nA IIB T4 Gc
II 3D – Ex tc IIIB T50°C Dc IP65 II 3D – Ex tc IIIB T52°C Dc IP65 II 3D – Ex tc IIIB T55°C Dc IP65 Cert. IMQ 13 ATEX 027 X Cert. IMQ 13 ATEX 027 X Cert. IMQ 13 ATEX 027 X
ATEX IEC309 PLUGS & INTERLOCK SOCKETS ZONE 22(D) - IP67 60 Atex GW678-
67 Atex GW606-
IP67
Vertical Interlock Sockets - 67 Atex IP67
6 6 6
GW67884 GW67888 GW67889
GW60615 GW60619 GW60620
6 6 6
GW67896 GW67900 GW67901
Plugs - 60 Atex
Ex tc IIIC T40 Dc X
Rated Voltage
Amp Rating Poles 16A
2P+E 3P+E 3P+N+E
230V
230V
32A
2P+E 3P+E 3P+N+E
63A
2P+E 3P+E 3P+N+E
230V
400V
400V
400V
Reference H 6 6 6
GW67873 GW67877 GW67878
GW60604 GW60608 GW60609
GW60627 GW60631 GW60632
ATEX PAINTED ENCLOSURES IP66 Zone 2(G) Zone 22(D)
Enclosure Code GW76291 GW76292 GW76293 GW76294 GW76295 GW76296 GW76297 c/w kit for external earthing Note: FLP Discounts Apply
Internal Dimensions(mm)
Pack/Carton Qty
128 x 103 x 57
32
91 x 91 x 54
155 x 130 x 58 178 x 156 x 75 239 x 202 x 85
294 x 244 x 114
392 x 298 x 149
40 24 16 8 4 1
Chassis Plates GW76272 GW76273 GW76274 GW76275 GW76276 GW76277
Box QTY -
10 10 10 5 5 5
Atex Class: II 3GD Ex nA IIC Gc Ex tc IIIC Dc -20°C ≤ Ta85 °C U
FLP
6
EXPLOSION PROOF LIMIT SWITCHES IP65 Ex II 2G Exed II CT6
Code
Roller Lever
Forked Roller Lever
Push Button
Push Roller
BZX51-6D
BZX51-6S
BZX51-6Z
BZX51-6L
Contacts: 1NO + 1NC. 6A@380VAC. Cable entry: M20 c/w cable gland. Suitable for: Zone 1 & 2. Group IIA, IIB, IIC class T6 or below
Roller Limit Switch Code
LSWR80
Description
Enclosure Size
Roller Limit Switch
120x120x90
Cable Entries
1 x Side (20mm)
Contacts 1NO+1NC. 10A@250VAC
PULLWIRE CONVEYOR TRIP SWITCH IP45 CTSFLP-D
Description
Code CTSFLP-S CTSFLP-D
Rope Accessories
Amps
10A 10A
Weight
12kg 18kg
Cable Entries 1 x Side 20mm 1 x Side 20mm
Suitable for: Zone 1 & 2. Group IIA, IIB, IIC class T6. Contacts: 1NO + 1NC. 10A@250VAC Per End
CTSFLP-S
Code
Description
Single Ended Trip Switch Double Ended Trip Switch
PWR
SB209331/6
Steel Wire. PVC sheathed rope 100 metre Ø5mm Red
Thimble 6mm
SB209332/6.5 Clamp 6.5mm
MET
SB209333/M8
SB209336/8 Tensioner 8mm
Eye bolt M8
EXPLOSION PROOF PLUGS & SOCKETS IP66
Material: GRP (Glass Fibre Reinforced Polyester Resin Suitable for use in: Zone1 & Zone 2 Zone 21 & Zone 22 Explosion Protection: T80°C IP66 112 GD EX de IIC T6G6 / EX ED A21 T80
Plug & Socket
Rated Rated Current (A) Voltage (V) 16A
32A
63A
7
200 - 250 380 - 415 480 - 500 200 - 250 380 - 415 480 - 500 200 - 250 380 - 415 480 - 500
Poles 2P+E 3P+N+E 3P+E 2P+E 3P+N+E 3P+E 2P+E 3P+N+E 3P+E
Plug BCZ8060-16/250/3P/T BCZ8060-16/415/5P/T BCZ8060-16/500/4P/T BCZ8060-32/250/3P/T BCZ8060-32/415/5P/T BCZ8060-32/500/4P/T BCZ8060-63/250/3P/T BCZ8060-63/415/5P/T BCZ8060-63/500/4P/T
FLP
Socket
Coupling Set
BCZ8060-16/250/3P/Z BCZ8060-16/415/5P/Z BCZ8060-16/500/4P/Z BCZ8060-32/250/3P/Z BCZ8060-32/415/5P/Z BCZ8060-32/500/4P/Z BCZ8060-63/250/3P/Z BCZ8060-63/415/5P/Z BCZ8060-63/500/4P/Z
BCZ8060-16/250/3P/L BCZ8060-16/415/5P/L BCZ8060-16/500/4P/L BCZ8060-32/250/3P/L BCZ8060-32/415/5P/L BCZ8060-32/500/4P/L -
ATEX WALL MOUNTING ENCLOSURES IP66 Ex e IIC Gb Ex tb IIIC Db LOM 12ATEX 3060U ATEX94/9/CE
Wall Mounting Enclosures
Mild Steel Grey Electric Orange
304L Stainless
ATX0302515-G ATX0403020-G ATX0404020-G ATX0504020-G ATX0604020-G ATX0606025-G ATX0705025-G ATX0806030-G ATX1008030-G
ATX0302515-INX ATX0403020-INX ATX0404020-INX ATX0504020-INX ATX0604020-INX ATX0606025-INX ATX0705025-INX ATX0806030-INX ATX1008030-INX
ATX0302515-O ATX0403020-O ATX0404020-O ATX0504020-O ATX0604020-O ATX0606025-O ATX0705025-O ATX0806030-O ATX1008030-O
• Zone 1 & 2, Zone 21 • -20ºC to +60ºC
Ex II 2G Ex e II T6
Size (mm) H x Wx D
Locks
400 x 300 x 200
1
300 x 250 x 150
1
2
400 x 400 x 200
1
2
500 x 400 x 200
2
2
600 x 400 x 200
2
2
600 x 600 x 250
2
2
700 x 500 x 250
2
2
800 x 600 x 300
2
2
1000 x 800 x 300
• Grey RAL7035 - Mild Steel • Electric Orange RAL2000 - Mild Steel
Hinges
2
3
3
• Polished 304 L Stainless Steel
• Include chassis plate & 4 wall brackets
EXPLOSION PROOF JUNCTION & TERMINAL BOXES Aluminium Terminal Boxes IP65 - Material: Aluminium Alloy, Yellow Powder coated No. of Terminals Fitting into box Size (mm) Code 2 LxWxD 2.5mm 4mm2 6mm2 10mm2 16mm2 190 x 132 x 127 20 18 15 12 10 BXJ-E-1 190 x 190 x 127 20 18 15 12 10 BXJ-E-2 250 x 190 x 127 30 28 22 18 15 BXJ-E-3 250 x 250 x 127 60 56 44 36 30 BXJ-E-4 300 x 200 x 150 80 72 60 48 – BXJ-E-5
No. of rows
No. of entries
1
2 bottom
1
3 bottom
1
2 bottom
2
3 bottom
2
4 bottom
• Suitable for use in: Zones 1 & 2, 21 & 22 • Terminals not included • For use with Atex approved terminals • Cable Entries: M20 x 1.5
Polyester Terminal Boxes IP65 - Material: Glass fibre reinforced Polyester resin No. of Terminals Fitting into box Size (mm) Code LxWxD 2.5mm2 4mm2 6mm2 10mm2 16mm2 BXJ8050-1 139 x 110 x 98 12 11 9 — — BXJ8050-2 220 x 130 x 109 25 23 18 15 — BXJ8050-3 260 x 179 x 120.5 30 27 22 18 15 BXJ8050-4 360 x 220 x 122 44 40 33 26 22 BXJ8050-5 360 x 360 x 122 88 80 66 52 44
Ex II 2G Ex e II T6
• Suitable for use in: Zones 1 & 2, 21 & 22 • Terminals not included • For use with Atex approved terminals • Cable Entries: M20 x 1.5
Code
Type
BXJ8050-20B/6-4
BXJ8050-20B/6-4 Terminal box
2 bottom M20 x 1.5
1
3 bottom M25 x 1.5
2
4 bottom M40 x 1.5
1
2 bottom M40 x 1.5
1
4 bottom M40 x 1.5
Die-Cast Aluminium
BHD51-G3/4I
Lightning Terminal Box
BHD-D/M25 Terminal Box
Glass fibre reinforced plastic
Aluminium Alloy, powder-coated
EX-Mark
II 2G Exe II T6
II 2G Exd II BT6 / CT6
Certificates
PTB 03 ATEX 1021
PTB 06 ATEX 1013
Gland Size
M25 x 1.5
G3/4 (not incl.)
M25 x 1.5 (not incl.)
Terminals
Posts 0.2-2.5mm² x 6
Posts 0.2-2.5mm²
DIN 2.5mm² x 6
120 x 120 x 60mm
Ø110 x 110H
Ø110 x 71H
Suitable for Zone 1, 2, 21 and 22
BHD51-G3/4I
1
Material
Size
BHD-D/M25
Engineering Plastic
No. of No. of Cable rows entries Entry Size
Temperature Range: -20˚C to +55˚C
FLP
Ideal for IIA, IIB and T6 Areas
8
EXPLOSION PROOF CONTROL STATIONS IP65 Code
-A1-E
-K1
BZA8050-K1 BZA8050-A1-G -A1-C BZA8050-A1-R BZA8050-A1-C BZA8050-A1-E BZA8050-A2-C
-A1-R
-A2-C
-A1-G
-A2-R/G
On/Off Selector Switch 1 x N/O (10A)
BZA8050-A2-R/G BZA8050-A3-R/G/L BZA8050-A3-R/G/E BZA8050-A3-R/G/S
-A3-R/G/E
-A3-R/G/L
-A3-R/G/S
Gland Enclosure Size Size H x W x D (mm)
Description
M25
107 x 85 x 87
Start Pushbutton 1N/O
M25
107 x 85 x 87
Stop Pushbutton 1 N/C
M25
107 x 85 x 87
Emg. Stop Twist to release 1N/C
M25
107 x 85 x 87
Emg. Stop Push-Pull 1N/C
M25
107 x 85 x 87
Emg. Stop (Twist to release 1N/C) & Start Pushbutton 1N/O
M25
139 x 85 x 87
Start/Stop 1N/O & 1N/C
M25
139 x 85 x 87
Start/stop and LED pilot light c/w 1N/O + 1N/C per button
M25
185 x 85 x 87
Start/stop and emergency stop (twist to release) c/w 1N/O + 1N/C per button
M25
185 x 85 x 87
Start/stop & selector 3 position stay put switch c/w 1NO + 1NC per button (switch can be used as auto-off-man)
M25
185 x 85 x 87
Explosion Protection: Ex II 2G Exed II CT6
Rated Working Voltage: 220VAC/380VAC
Material: Glass fibre reinforced polyester
Rated Working Current: 10A ATEX Classification Group II Category 2GD. Suitable for Zone 1, 2 and 21, 22 locations.
Explosion Proof - On/Off Switches for Zone 2,21 & 22
Suitable for use in BZA8050 Control Stations
202271EX
1 Lever 1 WAY 16A@250V Switch IP66
M25
80 x 62 x 38
202282EX
2 Lever 1 WAY 16A@250V Switch IP66
M25
80 x 62 x 38
202276EX
1 Lever 2 WAY 16A@250V Switch IP66
M25
80 x 62 x 38
EXPLOSION PROOF PUSHBUTTONS & PILOT LIGHTS
2-Position stay-put
Colour
Pushbutton Flush
Pilot Light Head
Selector Switch EX8050-SS
Red
●
EX8050-R
EX8050-PLR
Green
●
EX8050-G
EX8050-PLG
Yellow ●
EX8050-Y
EX8050-PLY
White
–
EX8050-PLW
●
Contact Blocks
Description 1N/O 1N/C
9
Code
EX8050-NO EX8050-NC
110VAC
EX8050-EMG
LED Lamp Blocks
Description 24VAC
EMG-Stop Twist Release
Code
EX8050*-24VAC EX8050*-110VAC
EMG-Stop Push/Pull Button
On/Off Key Switch
EX8050-40093
EX8050-KS
Isolating Switch On/Off
Description 2 Pole 10A 4 Pole 10A
Code
EX8050-2P EX8050-4P
230VAC EX8050*-230VAC *Add colour of lamp to code: ● R (Red), ● G (Green), ● Y (Yellow), ● W (White)
FLP
FLAMEPROOF CONTROL STATIONS 1 Way Control Stations - Zone 1 Group IIA, IIB, IIC
PBS71
Code Cast Iron PBS71-START-* PBS71-1-* PBS71-2-* PBS71-3-* PBS71-6-* CT/KMS-93-†
Description
Start Station Emergency Stop (spring return) Padlockable Stop Station Emergency Stop (push/pull) Emergency Stop Padlockable Mining Key Switch *Add ‘D’ for 1 x Top & 1 x Bottom 20mm entries, ‘B’ for 2 x 20mm bottom entries †SC = shuttle car key, CM = continuous miner, DV = feeder bunker CT/KMS-93 PBS72 RBS-81-2
RBS-84 Ex d 1T4
Ex d 1T4
2 Way Control Stations Start/Stop Station PBS72-* Emergency Stop (push/pull)/Start PBS72-3-*
b b b b b a
b b
*Add ‘D’ for 1 x Top & 1 x Bottom 20mm entries, ‘B’ for 2 x 20mm bottom entries Enclosure Size Code: H x W x D (External) a = 120 x 120 x 90 b = 140 x 100 x 135
RBS-85
RBS-86
1 & 2 Way Fabricated FLP Control Stations - Material: 350WA - Silver Cadium Plated Base Size (mm) Weight Cable Entries 20mm Description Code L x H x Ø 1 x Top & 1 x Bottom 4.5kg Start Station 125 x 125 x 150 RBS-81 1 x Top & 1 x Bottom 4.5kg Start/Stop Station 125 x 125 x 150 RBS-81-2 1 x Top & 1 x Bottom 4.5kg Emergency Stop (spring return) 125 x 125 x 150 RBS-82 1 x Top & 1 x Bottom 4.5kg Padlockable Stop Station 125 x 125 x 150 RBS-83 1 x Top & 1 x Bottom 4.5kg Emergency Stop (push/pull) 125 x 125 x 150 RBS-84 1 x Top & 1 x Bottom RBS-85 4.5kg Emergency Stop Padlockable 125 x 125 x 150 1 x Top & 1 x Bottom RBS-86 4.5kg Mining Key Switch 125 x 125 x 150 Zone 1 Group IIA, IIB, IIC
Intertrunk - Material 300WA Steel Code
Description
INTTRUNK
Intertrunk 2 sides open c/w 32mm flanges with 4x 14mm holes
Flameproof Mains Failure Indicator & Siren Code
Description
MAIN-FC Voltage Monitor with Flasher & Siren • Monitoring Voltage 230VAC • Battery backup 4 hours run time on mains failure • Flasher & Siren on when mains fail Flameproof Jet Fan Enclosure - 1000V with Victor Socket - 250A Code
Description
JETFAN-E1
Jet fan panel wired with Victor socket
• Start/Stop Buttons • 3 x Terminals with Diode Ex d I/IIB + H2
Enclosure Size Code
Flameproof Battery & Breaker Box Code
Description Description
Size (mm) H x L x W 210 x 160 x 163
Size (mm) H x L x W
260 x 160 x 185
Size (mm) H x L x W
250 x 250 x 153
Size (mm)Size (mm) H x L xHWx L x W
Flameproof Flameproofenclosure enclosuresuitable for battery for 12V battery Ah 12V 35-100Ah525 x 317 525 x 221x 317 x 221 BOXBATT-12V Note: Battery Box without battery. For Batteries see page 91
Flameproof Breaker Box Code
Description Description
BOXBREAK-600A Flameproof enclosure for breaker 600A, 1000V
Size (mm)Size (mm) H x L xHWx L x W
525 x 317 x 221
• Circuit breaker Box complete with 600A,1000V, 3 Pole Terasaki Breaker • Cable Entries 5 x M32
FLP
10
FLAMEPROOF ISOLATORS
Polyester Enclosed Isolators - Padlockable 8mm - Rated working voltage: 220VAC/380VAC Description
Entry
BZZ8050-16/2
16A 2-Pole Isolator Padlockable
2 x M25
139 x 110 x 109
16A 3-Pole Isolator Padlockable
2 x M25
139 x 110 x 109
32A 2-Pole Isolator Padlockable
2 x M25
220 x 130 x 109
32A 3-Pole Isolator Padlockable
2 x M25
BZZ8050-16/3 BZZ8050-32/2 -16/2 / -16/3
BZZ8050-32/3
-32/2 / -32/3
ISO80
Size (mm) Lx H xW
Code
220 x 130 x 109 • Explosion protection: Ex II 2G Exed II CT6 • Material: Glass fibre reinforced polyester ATEX Classification Group II Category 2GD. Suitable for Zones 1, 2 and 21, 22 locations Diecast Enclosed Isolators - Padlockable 8mm
Code
Description
ISO80/1/20 ISO80/3/20 ISO80/3/32 ISO160/3/32 ISO160/3/40 ISO160/3/63 ISO160/3/80
20 Amp 2 Pole Isolator 20 Amp 3 Pole Isolator 32 Amp 3 Pole Isolator 32 Amp 3 Pole Isolator 40 Amp 3 Pole Isolator 63 Amp 3 Pole Isolator 80 Amp 3 Pole Isolator
Enclosure Size Code
Cable Entries
a
1 x Top & 1 x Bottom
a
1 x Top & 1 x Bottom
a
1 x Top & 1 x Bottom
g
2 x Bottom
g
2 x Bottom
g
2 x Bottom
g
2 x Bottom
Enclosure Size Codes: H x W x D (External), a = 120 x 120 x 90, g = 255 x 150 x 155. Zone 1 Group IIA,IIB,IIC.
ISO160
Fabricated Enclosed Isolators - Padlockable 8mm - Material 350WA - Silver Cadium Plated Size (mm) Code Description Weight Cable Entries 20mm Ø x H 1 x Top & 1 x Bottom 25 Amp 2 Pole Isolator 4.5kg 150 x 120 RIS25/2P 1 x Top & 1 x Bottom 25 Amp 3 Pole Isolator 4.5kg 150 x 120 RIS25/3P 1 x Top & 1 x Bottom 32 Amp 2 Pole Isolator 4.5kg 150 x 120 RIS32/2P 1 x Top & 1 x Bottom 32 Amp 3 Pole Isolator 4.5kg 150 x 120 RIS32/3P 1 x Top & 1 x Bottom 40 Amp 3 Pole Isolator 8.0kg 200 x 150 RIS40/3P 1 x Top & 1 x Bottom 63 Amp 3 Pole Isolator 8.0kg 200 x 150 RIS63/3P 1 x Top & 1 x Bottom 80 Amp 3 Pole Isolator 8.0kg 200 x 150 RIS80/3P
Padlockable
Zone 1 Group IIA, IIB, IIC
FLAMEPROOF JUNCTION BOXES Flameproof Junction Boxes Code
Description
KBE2M20L-2 KBE2M25L-2 KBE4M20L-2 KBE4M25L-2
K-Box - Empty with 2xM20 Hole K-Box - Empty with 2xM25 Hole K-Box - Empty with 4xM20 Hole K-Box - Empty with 4xM25 Hole
No of Cable Entries
Size Ø x H
2 x M25
145 x 104
4 x M20
145 x 104
4 x M25
145 x 104
2 x M20
145 x 104
OTHER FLAMEPROOF EQUIPMENT Flameproof Level Line Lazer
Ex d1/II B
11
Description
LLL24-HOR LLL24-VER
Flameproof Level Line Laser - Horizontal 12/24VDC
Code
Description
VMETFLP-50V AMETFLP-50A HMETFLP-24V
Flameproof Volt Meter 0 - 50VDC
Flameproof Level Line Laser - Vertical 12/24VDC
Flameproof Volt/Amp/Hour Meter
Ex d1/II B
VMETFLP
Code
AMETFLP
HMETFLP
Flameproof Amp Meter 0 - 50ADC
Flameproof Hour Meter 12 - 24VDC
FLP
Size Ø x H
Watts
112 x 148
1W
112 x 148
Size Ø x H
112 x 148 112 x 148 112 x 148
1W
FLAMEPROOF STARTERS Zone 1 Group IIA, IIB, IIC
Direct On Line Starter – No Terminal Box AC3 kW 400V 525V 4
5.5
5.5
7.5
7.5
10.5
11
15
15
18.5
18.5
22
22
30
30
37
37
45
45
55
Overload D.O.L. Range Code 7-10A FDL09 9-13A FDL12 12-18A FDL18 17-25A FDL25 23-32A FDL32 33-50A FDL40 33-50A FDL50 43-65A FDL65 54-80A FDL80 83-90A FDL95
Enclosure With Size Code Isolator c
/S
Enclosure Size Code
c
/S
d
c
/S
d
d
/S
e
d
/S
e
f
/S
f
f
/S
f
f
/S
f
f
/S
f
f
/S
f
d
Coil Voltage AC
U = 240V (170-280V) N = 415V (291-465V) SF = 550V (467-605V)
Enclosure Size Codes: H x W x D (External) c = 190 x 140 x 135, d = 320 x 210 x 190, e = 320 x 150 x 135, f = 450 x 330 x 220
Ex d1
Flameproof Starter Panel - 525/100V Dual Voltage Code
Description
FLS-XLW-*A
Anglo Spec Starter Panel with large round window Sasol Spec Starter Panel with square window (Waterproof panel) IP65 Exxaro Spec Starter with small round window Starter Panel with small round window
FLS-XSQ-*S
Internal Sizes (mm) L x H xW
280 x 280 x 220 280 x 280 x 220
380 x 300 x 220 FLS-XSM-*E 280 x 280 x 220 FLS-XSM-* 280 x 280 x 220 Starter Panel without window FLS-XNN-* * Add KW to Code Range: 3.7KW, 4KW, 5.6KW, 7.5KW, 11KW, 15KW, 18.5KW, 22KW, 30KW, 37KW S for Sasol Spec, A for Anglo Spec and E for Exxaro Spec
Mine Specifications
• Sasol Spec Starter Enclosure: Includes Small window with O-ring, Contactor, M20 & Transformer. • Anglo Spec Starter Enclosure: Includes M/R31 Big window, Contactor, M20, Transformer with 1000V fuse holders & Victor socket. • Exxaro Spec Starter Enclosure: M/R401 with contactor, M20, Transformer with 1000V fuse holders & Victor socket Ex d1
Ex d1
Flameproof Camera - Supply Volts 12/24VDC Code
Description
FCA-CAM-1
Flame Proof Camera + 70mm Apeture
• 7.5” Screen c/w 8m cable & quick connectors • Camera Range ± 15 meters with infra-red LEDs
Flameproof Gulley Boxes
Size (mm) Ø x H 112 x 93
Size (mm) H x L x W
Code
Description
GULL-101 GULL-102 GULL-103
Gulley Box Incomer, Main & Feeder Compartments 730 x 988 x 268 Gulley Box Incomer, Main & Feeder Compartments 986 x 943 x 300
Gulley Box Incomer, Main & Feeder Compartments 1010 x 650 x 250 • Can be customised to user specification. • All other panels can be made to order with the enquiry form supplied Ex d 1T4
Flameproof Compressor Panel - Dual Voltage 525/1000V System
Code
Description
COMP-FP-37 COMP-FP-60 COMP-FP-150
Compressor Panel + Window 18.5 - 30kW Compressor Panel + Window 37 - 60kW
Internal Sizes (mm) H x L x W
380 x 300 x 220 435 x 700 x 220
Compressor Panel + Window 90 - 150kW 585 x 435 x 226 • Complete with Circuit Breaker, Contactor, Electronic Overload & Transformer • Cable Entries 5 x M32
FLP
12
FLAMEPROOF ACCESSORIES Adaptor Plates & Socket Blocks
Description
Code
APLT-3.3 APLT-6.6 SOC-AP40 SOC-AP50 SOC-APV250 SOC-AP90D
3.3/6.6kVA Adaptor 90° Socket Adaptor
3,3-kVA Adaptor Plate for Transformer Box 6,6-kVA Adaptor Plate for Transformer Box Socket Adaptor with M40 Entry Socket Adaptor with M50 Entry Socket Adaptor (Intertrunk to Proof/Victor 250A socket) 90° Socket Adaptor
Socket Adaptor
FLAMEPROOF INDICATION LIGHTS
Live Line Indicators - 1000V
Code FLP-EV-1KV
Waterproof Push Buttons
Thread Size: M25 Size: Ø38mm
Description
3-Row Cluster Light (Red, Green & Amber) 12/24VDC
Colour
Red Blue Green White Amber
*Add voltage: 24 (12/24VDC), 110 (110VAC) or 230 (230VAC)
Code FLP-EA-R* FLP-EA-BL* FLP-EA-GN* FLP-EA-WH* FLP-EA-A*
FLAMEPROOF PUSH BUTTONS
Head Size: 25(H) x 30(Ø)mm Body Size: 80mm
Mounting Hole - M25 Contact 10A@240V
Size: Ø 85mm x 25mm Thread Size: M25
Code FLP-EP3-24
3-LED Live Line Indicator In Brass Body •1000VAC •RED Light •M25 Cable Entry •Size: Ø60 x 110(L)mm
Mounting Hole - M20
LED Indication Lights
c/w male & female connectors
Description
Description
Indicator Lights
1NC
Test PBUTM20-TEST PBUTM25-TEST
1NO
Reset PBUTM20-RES PBUTM25-RES
Stop PBUTM20-STPWP PBUTM25-STPWP
Test PBUTM20-TESTWP PBUTM25-TESTWP
Reset PBUTM20-RESWP PBUTM25-RESWP
Stop PBUTM20-STP PBUTM25-STP
Start PBUTM20-ST PBUTM25-ST 1NO
1NO
Head Size: 32.5(H) x 40(Ø)mm Body Size: 80mm
Description M20
M25
Contact 10A@240V
Emergency Stop Push Buttons Head Size: 43(H) x 60(Ø)mm Body Size: 80mm
Description
Start PBUTM20-STWP PBUTM25-STWP 1NO
Push - Pull
M20 M25 Contact 10A@250V For additional contacts refer to Page 190
13
1NC
1NO
Push - Pull
E/Stop
PBUTM20-ES PBUTM25-ES
E/Stop Lockable
PBUTM20-ESLK PBUTM25-ESLK
1NC
1NC
FLP
1NO
Toxic Gas Sensors - Not
TOXIC GAS SENSOR
Wheatstone bridge type combustible gas sensor Sensor diameter: 20.25mm
c/w gas sensor with gasket, calibrated 4-20mA digital transmitter board and mounting posts. Gasket sensor diameter: 32.3mm
Code
COMPLETE UNIT
Designed for mounting in any enclosure
Colour
Type
Explosion Proof Gas Sensor
CH-A3-BF
Carbon Monoxide Green CO-BF-* Hydrogen Sulphide Orange H2S-BE-* Sulphur Dioxide Red S02-BE-1 *Add sensor range to code: 1 (0-500ppm), 2 (0-2000ppm) Input voltage: 10-30VDC (loop powered) Connection: 2-Pin Molex (22-27-2021) CE Approval: BS EN 61326 (Industrial)
440P55
Code
CH-A3-BF 440P55
Type
Explosive Gas Pellistor PCB socket for Pellistor
CH-A3-BF detects: Propane, Ethylene, Nonane, Acetylene, Butane, Isobutylene, Hydrogen, n-Pentane and Carbon Monoxide Pellistor and PCB Socket to be ordered separately EX II 2G Ex d IIC T4 SIRA 07 ATEX 1088X
EXPLOSION PROOF FANS
Explosion Proof IP55 - 230VAC, Maximum Operating Temperature 135°C Size (mm) Explosion Flow Volts kW H x WxØ Proof Fans Rate 340 x 340 x 260 0.12 900m3/h 230 OW354 390 x 390 x 312 0.14 1500m3/h 230 OW355 460 x 460 x 365 0.16 230 2250m3/h OW356 510 x 510 x 415 0.18 230 2900m3/h OW350 630 x 630 x 515 0.21 230 4500m3/h OW351 510 x 510 x 415 0.23 2900m3/h OW361* Ex-Atex Approved N.03 Atex 251 *Supply Voltage: 400VAC-3PH
Grill
Fan
Grill Code OW595 OW596 OW597 OW598 OW599 OW598
FAN
EXPLOSION PROOF ACCESSORIES
Class 1 Zone 1 Cert. MS787/J608 For use on Exd equipment to SABS 314.
Class 1 Zone 1 Cert. MS787/J206
S.W.A. Glands Size Code 0 FSG-0 1 FSG-1 2 FSG-2 3 FSG-3 4 FSG-4
Supplied with Shroud
For Armored Cable Double Seal IP66
Cable Glands Explosive Areas IP68 5 Bar with strain relief black Polyamide Group II Category 2GD, ATEX1087X
Code
124M20EX03 124M25EX03 124M32EX03
Size
Size Cable Size Ø
M20
6-12mm
M25
13-18mm
M32
18-25mm
Compression Glands Size Code 00 FCG-00 0 FCG-0 1 FCG-1 2 FCG-2 3 FCG-3 4 FCG-4 5 FCG-5 6 FCG-6 Compression Glands IP65
20mm 25mm 32mm Ex II 2G Exd IIC 40mm
Hole Plugs
Code
EPG-709002 EPG-709004 EPG-709006 EPG-709008
Size
20mm 25mm 32mm Ex II 2G Exe II 40mm
Code
EPC-706001 EPC-706002 EPC-706003 EPC-706004 L
L
Size 20 25 32 40 50
Code Alum. Alloy BA-715001 BA-715002 BA-715003 BA-715004 BA-715005
Length L (mm) 17 17 20 20 20
Ex II 2G Exd IIC Material: Aluminium Alloy, carbonate Steel Zinc-Plated
Code Brass Nickel Plated BPT-715011 BPT-715012 BPT-715013 BPT-715014 BPT-715015
Length L (mm) 17 17 20 20 20
Code Plastic
BZ-714002 BZ-714003 BZ-714004 BZ-714005 BZ-714006
Length L (mm) 10 12 12 14.5 15
Ex II 2G Exe II
FLP
14
FLAMEPROOF ACCESSORIES 90° Glands & Keeper Plates
GLND900
Flameproof Bushings
Ø
Description
Code BFLPM32MOT BFLPM20THR BFLPM25THR BFLPM32THR
Code GLND90050.8 GLND90063.5 GLND90076.2
Description
Size Ø
90° Compression Glands & Keeper Plates FLP
63.5mm
90° Compression Glands & Keeper Plates FLP
76.2mm
90° Compression Glands & Keeper Plates FLP
BFLPM32MOT
BFLPM32THR
50.8mm
BFLPM20THR
M32 Motor Bushing with M12 Studs M20 through Bushing with 6 x 1.5mm² Wires (1m Total Length) M25 through Bushing with 12 x 1.5mm² Wires (1m Total Length) M32 through Bushing with 20 x 1.5mm² Wires (2m Total Length)
Adaptors
Blanking Plug
Reducers
Code ADA3/4NPTM25F ADAM32M40F ADAM25M32F
Description
¾ NPT to M25 Adaptor M32 to M40 Adaptor M25 to M32 Adaptor
Code REDM25M16F REDM25M20F REDM32M25F REDM40M32F REDM50M25F REDM63M50F
Description
M20 to M16 reducer M25 to M20 reducer M32 to M25 reducer M40 to M32 reducer M50 to M25 reducer M63 to M50 reducer
Code BPLGM20F BPLGM25F BPLGM32F BPLGM40F BPLGM50F
High Security Key Switches
Ronnis Key Switches
Abloy Key Switch Barrel
Description
M20 Blanking Plug M25 Blanking Plug M32 Blanking Plug M40 Blanking Plug M50 Blanking Plug
Abloy Key Switch Brass Body
Code
Description
KEYSW-SR-1 KEYSW-SP-2
Ronnis Keyswitch (Spring Return) x 2 Keys Ronnis Keyswitch (Stay Put) x 2 Keys
Code Description Code KEYSW-AB3K Abloy key switch barrel only with 3 keys KEYSW-AB1 Roof bolter key switch barrel & 3 keys (RB engraved) KEYSW-RB Shuttle car key switch barrel & 3 keys (SC engraved) KEYSW-SC Continuous miner key switch barrel & 3 keys (CM engraved) KEYSW-CM KEYSW-PDS PDS key switch barrel & 3 keys (PDS engraved) Abloy Keys Only Abloy Keys Only - 3 Keys KEY-AB KEY-ABMAS Abloy Master Key - 3 Keys Flameproof Quick Connectors - with or without cable Description
Code FQC-PL-*-2M FQC-SC-*-3M FQC-SC-*-6M
Quick Connector Plug (Male) Quick Connector Socket (Female) Quick Connector Socket(Female) * Add no. of way to code: 04, 05, 19
1000V Fuse Holders & Fuses
F114 F602
L
15
Code P114 F602*
Description
1000V Fuse Holder For 10 x 85 Fuse 1500V Fuse Size 10 x 85 Fuse
* Add Amps to code: 2A, 4A, 6.3A, 10A, 16A
FLP
Description
Abloy key switch barrel & brass body & 1NO 10A Contact incl 3 keys
Wire Length 2 meters 3 meters 6 meters
MINING STARTERS - NON FLAMEPROOF IP54 Mining Winch Starters
All winch starters are standard with a system voltage of 525VAC 3PH supplied in an IP54 mild steel enclosure.
Code WINCHS-22* WINCHS-37* WINCHS-45* WINCHS-55*
Description
Code CONS-11* CONS-15 CONS-18* CONS-22* CONS-30* CONS-37* CONS-45* CONS-55* CONS-75*
Description
11KW at 525V N/FLP 15KW at 525V N/FLP 18.5KW at 525V N/FLP 22KW at 525V N/FLP 30KW at 525V N/FLP 37KW at 525V N/FLP 45KW at 525V N/FLP 55KW at 525V N/FLP 75KW at 525V N/FLP *Add Control Volts to Code: F(110VAC), U(240VAC), SF(550V)
Description
Mining Pump Starters Code PUMPS-07* PUMPS-11* PUMPS-15* PUMPS-18* PUMPS-22* PUMPS-30* PUMPS-37* PUMPS-45* PUMPS-55*
Description
7.5KW at 525V N/FLP 11KW at 525V N/FLP 15KW at 525V N/FLP 18.5KW at 525V N/FLP 22KW at 525V N/FLP 30KW at 525V N/FLP 37KW at 525V N/FLP 45KW at 525V N/FLP 55KW at 525V N/FLP *Add Control Volts to Code: F(110VAC), U(240VAC),SF(550V)
All vacuum pump starters are standard with a system voltage of 525VAC 3PH, supplied in an IP54 mild steel enclosure.
Description
DOL Mining Starters Code Description DOL 4KW at 525V N/FLP DOLMS-04* DOL 5.5KW at 525V N/FLP DOLMS-05* DOL 7.5KW at 525V N/FLP DOLMS-07* DOL 11KW at 525V N/FLP DOLMS-11* DOL 15KW at 525V N/FLP DOLMS-15* DOL 18.5KW at 525V N/FLP DOLMS-18* DOL 22KW at 525V N/FLP DOLMS-22* DOL 30KW at 525V N/FLP DOLMS-30* DOL 37KW at 525V N/FLP DOLMS-37* DOL 45KW at 525V N/FLP DOLMS-45* DOL 55KW at 525V N/FLP DOLMS-55*
7.5KW at 525V N/FLP 11KW at 525V N/FLP 15KW at 525V N/FLP 18.5KW at 525V N/FLP 22KW at 525V N/FLP 30KW at 525V N/FLP 37KW at 525V N/FLP 45KW at 525V N/FLP 55KW at 525V N/FLP *Add Control Volts to Code: F(110VAC), U(240VAC), SF(550V)
Mining Vacuum Fan Starters
*Add Control Volts to Code: F(110VAC), U(240VAC),SF(550V)
All fan starters are standard with a system voltage of 525VAC 3PH, supplied in an IP54 mild steel enclosure.
Code FANVS-07* FANVS-11* FANVS-15* FANVS-18* FANVS-22* FANVS-30* FANVS-37* FANVS-45* FANVS-55*
Code MONWS-04* MONWS-05* MONWS-07* MONWS-11* MONWS-15* MONWS-18* MONWS-22* MONWS-30* MONWS-37*
All pump starters are standard with a system voltage of 525VAC 3PH, supplied in an IP54 mild steel enclosure.
Mining Vacuum Pump Starters
Code VACPS-07* VACPS-11* VACPS-15* VACPS-18* VACPS-22* VACPS-30* VACPS-37* VACPS-45* VACPS-55*
All winch starters are standard with a system voltage of 525VAC 3PH, supplied in an IP54 mild steel enclosure.
4KW at 525V N/FLP 5.5KW at 525V N/FLP 7.5KW at 525V N/FLP 11KW at 525V N/FLP 15KW at 525V N/FLP 18.5KW at 525V N/FLP 22KW at 525V N/FLP 30KW at 525V N/FLP 37KW at 525V N/FLP *Add Control Volts to Code: F(110VAC), U(240VAC), SF(550V)
22KW at 525V N/FLP 37KW at 525V N/FLP 45KW at 525V N/FLP 55KW at 525V N/FLP *Add Control Volts to Code: F(110VAC), U(240VAC), SF(550V)
Conveyor Starters
Mono Winch Starters
Mining Drill Rig Starters
All drill rig starters are standard with a system voltage of 525VAC 3PH, supplied in a steel enclosure.
Description
7.5KW at 525V N/FLP 11KW at 525V N/FLP 15KW at 525V N/FLP 18.5KW at 525V N/FLP 22KW at 525V N/FLP 30KW at 525V N/FLP 37KW at 525V N/FLP 45KW at 525V N/FLP 55KW at 525V N/FLP
Code DRST-55* DRST-75*
Description
55KW at 525V N/FLP 75KW at 525V N/FLP *Add Control Volts to Code: F(110VAC), U(240VAC),SF(550V)
Mining Fan Starters
All fan starters are standard with a system voltage of 525VAC 3PH with control fuse protection and 110 or 230V for the alarm circuit.
Code FANS-07* FANS-11* FANS-15* FANS-22*
Description
7.5KW at 525V N/FLP 11KW at 525V N/FLP 15KW at 525V N/FLP 22KW at 525V N/FLP *Add Control Volts to Code: F(110VAC), U(240VAC),SF(550V)
*Add Control Volts to Code: F(110VAC), U(240VAC), SF(550V)
• Non-Plug-In Starters • Mining Glands fitted • Control Circuit Protection : 550V - 2 Fuses : 110 or 240V - Transformer with 3 Fuses
Note: All of the above Mining Starters can be manufactured to customer requirements.
FLP
16
MINING GULLEY BOXES - NON FLAMEPROOF IP54 Gulley Boxes Incomers - 250A Bus Code Top Box
Incomer
Size (mm) H x Wx D
Description
Harmony Mine Spec GBINT-250-HA-** 250A Tee Box Incomer Harmony Spec Tee Box Incomer Other Mines Spec GBIN-250-*-** 250A Gulley Box Incomer
800 x 280 x 185 (Vertical Box) 180 x 515 x 185 (Top Box) 600 x 200 x 190
GBIN-250 * Add mine to code: EX(Exxaro), DE(De Beers Consolidated Mines), PE(Petra), AA(Anglo American), AGA(Anglo Gold Ashanti), GF(Gold Fields), HA(Harmony Gold), AP(Anglo American Amplats)
** Add control volts to code: SF(550V), Z(1000V)
Other mine Incomer
Gulley Boxes Feeders - 250A Bus
Feeder
GBFE
Code
Description
GBFE-40-*-** GBFE-60-*-** GBFE-100-*-**
40 A Feeder box 60A Feeder box 100A Feeder box
* Add mine to code: EX(Exxaro), DE(De Beers Consolidated Mines), PE(Petra), AA(Anglo American), AGA(Anglo Gold Ashanti), GF(Gold Fields), HA(Harmony Gold), AP(Anglo American Amplats)
** Add control volts to code: SF(550V), Z(1000V)
Note: All gulley boxes incomer fitted with Terasaki integrated earth leakage circuit breaker. Other specifications available on request Gulley Boxes - Lighting Feeders (Transformers) Code GBFEL-S3 GBFEL-S4 GBFEL-S5
Description
Lighting Transformer Box 3KVA 550V Lighting Transformer Box 4KVA 550V Lighting Transformer Box 5KVA 550V
Complete with Terasaki Incoming Circuit Breaker, Gewiss output Circuit Breakers 4 x 6A and Isolating Transformer 550V/230VAC
OTHER STARTERS - NON FLAMEPROOF
Flitting Panels Non-Flameproof - 110kW 550V Forward/Reverse DOL Starter
Code
FLITPAN
Description
Exxaro Spec Flitting panel
Incl. 2 x 110kW DOL Contactors, MCCB, transformers with fuse holders & terminals. With Victor plug and New Elec WA Electronic Overload
Note: Other combinations and specifications manufactured to your order.
Heavy Duty Starter Non-Flameproof Mining Starter - 525V
Code
Description
HDFST-*-* HDPST-*-* HDWST-*-*
Heavy duty DOL fan starter Heavy duty DOL pump starter Heavy duty DOL winch starter
Size mm L xW xD
730 x 988 x 268 986 x 943 x 300 1010 x 650 x 250
* Add kW rating to code: 03(3.7kW), 05(5.5kW), 07(7.5kW), 11(11kW), 18(18.5kW), 22(22kW), 37(37kW), 45(45kW), 75(75kW),
* Add control voltage to code: F(110V) or U(240V)
17
FLP
VICTOR PLUGS & SOCKETS 650/1100VAC Flameproof 250Amp 4 Pin Screw Type Plugs
Non-Flameproof 250Amp 4 Pin Screw Type Plugs
Description Code Z100001/101 Flameproof 250A 4 Pin Plug for 4mm2 Z100001/102 Flameproof 250A 4 Pin Plug for 6mm2 Z100001/104 Flameproof 250A 4 Pin Plug for 16mm2 Flameproof 250A 4 Pin Plug for 16mm2 Z100001/114 Flameproof 250A 4 Pin Plug for 25mm2 Z100001/115 Flameproof 250A 4 Pin Plug for 35mm2 Z100001/116 Flameproof 250A 4 Pin Plug for 50mm2 Z100001/117 Flameproof 250A 4 Pin Plug for 70mm2 Z100001/118 Z100001/126 Flameproof 250A 4 Pin Plug for 35mm2 Z100001/127 Flameproof 250A 4 Pin Plug for 50mm2 Flameproof 250Amp 4 Pin Screw Type Sockets
Code Z100002/101 Z100002/102 Z100002/104 Z100002/114 Z100002/115 Z100002/116 Z100002/117 Z100002/118 Z100002/126 Z100002/127
Description
Flameproof 250A 4 Pin Socket for 4mm Flameproof 250A 4 Pin Socket for 6mm2 Flameproof 250A 4 Pin Socket for 16mm2 Flameproof 250A 4 Pin Socket for 16mm2 Flameproof 250A 4 Pin Socket for 25mm2 Flameproof 250A 4 Pin Socket for 35mm2 Flameproof 250A 4 Pin Socket for 50mm2 Flameproof 250A 4 Pin Socket for 70mm2 Flameproof 250A 4 Pin Socket for 35mm2 Flameproof 250A 4 Pin Socket for 50mm2 2
Cable Type
Description Cable Type Code 41 Z7100001/101 Non-Flameproof 250A 4 Pin Plug for 4mm2 41 Z7100001/102 Non-Flameproof 250A 4 Pin Plug for 6mm2 41 Z7100001/104 Non-Flameproof 250A 4 Pin Plug for 16mm2 61A Z7100001/114 Non-Flameproof 250A 4 Pin Plug for 16mm2 61A Z7100001/115 Non-Flameproof 250A 4 Pin Plug for 25mm2 61A Z7100001/116 Non-Flameproof 250A 4 Pin Plug for 35mm2 61A Z7100001/117 Non-Flameproof 250A 4 Pin Plug for 50mm2 61A Z7100001/118 Non-Flameproof 250A 4 Pin Plug for 70mm2 61B Z7100001/126 Non-Flameproof 250A 4 Pin Plug for 35mm2 61B Z7100001/127 Non-Flameproof 250A 4 Pin Plug for 50mm2 Non-Flameproof 250Amp 4 Pin Screw Type Sockets
Cable Type
Code Z710002/101 Z710002/104 Z710002/115 Z710002/116 Z710002/117 Z710002/118
41 41 41 61A 61A 61A 61A 61A 61B 61B
41 41 41 61A 61A 61A 61A 61A 61B 61B
Flameproof 425Amp 4 Pin Screw Type Plugs
Code Z120001/100 Z120001/110 Z120001/111 Z120001/112 Z120001/113 Z120001/114 Z120001/115 Z120001/116 Z120001/117 Z120001/122 Z120001/123 Z120001/124 Z120001/125 Z120001/126 Z120001/127 Z120001/134 Z120001/135 Z120001/136 Z120001/137
Description
Flameproof 400A 4 Pin Plug for 16mm2 Flameproof 400A 4 Pin Plug for 16mm2 Flameproof 400A 4 Pin Plug for 25mm2 Flameproof 400A 4 Pin Plug for 35mm2 Flameproof 400A 4 Pin Plug for 50mm2 Flameproof 400A 4 Pin Plug for 70mm2 Flameproof 400A 4 Pin Plug for 95mm2 Flameproof 400A 4 Pin Plug for 120mm2 Flameproof 400A 4 Pin Plug for 150mm2 Flameproof 400A 4 Pin Plug for 35mm2 Flameproof 400A 4 Pin Plug for 50mm2 Flameproof 400A 4 Pin Plug for 70mm2 Flameproof 400A 4 Pin Plug for 95mm2 Flameproof 400A 4 Pin Plug for 120mm2 Flameproof 400A 4 Pin Plug for 150mm2 Flameproof 400A 4 Pin Plug for 70mm2 Flameproof 400A 4 Pin Plug for 95mm2 Flameproof 400A 4 Pin Plug for 120mm2 Flameproof 400A 4 Pin Plug for 150mm2
Description
Non-Flameproof 250A 4 Pin for 4mm Non-Flameproof 250A 4 Pin for 16mm2 Non-Flameproof 250A 4 Pin for 25mm2 Non-Flameproof 250A 4 Pin for 35mm2 Non-Flameproof 250A 4 Pin for 50mm2 Non-Flameproof 250A 4 Pin for 70mm2 2
Cable Type 41 41 61A 61A 61A 61A
Flameproof 425Amp 4 Pin Screw Type Sockets
Cable Type 41 61A 61A 61A 61A 61A 61A 61A 61A 61B 61B 61B 61B 61B 61B 63 63 63 63
Code Z120003/10 Z120003/20 Z120003/30 Z120003/40 Z120003/50 Z120003/60 Z120003/70 Z120003/80 Z120003/30 H Accessories
Code 002706 037001
Description
Cable Type
Description
Cable Type
Flameproof 425A 4 Pin Socket for 150mm2 Flameproof 425A 4 Pin Plug for 120mm2 Flameproof 425A 4 Pin Plug for 95mm2 Flameproof 425A 4 Pin Plug for 70mm2 Flameproof 425A 4 Pin Plug for 50mm2 Flameproof 425A 4 Pin Plug for 35mm2 Flameproof 425A 4 Pin Plug for 25mm2 Flameproof 425A 4 Pin Plug for 16mm2 Flameproof 425A 4 Pin Plug for 95mm2
200/250A Test Plug 300/425A Test Plug
NA NA NA NA NA NA NA NA NA
NA NA
Note: For testing the operation of the Pilot Circuit and Live Indication. Dual Voltage 650/1100VAC.
FLP
18
EXPLOSION PROOF LIGHTING Flameproof Spot Lights - Material Mild Steel Zinc Plated LED Light Description Code Power Output 49 LUX at 5m Flameproof Spotlight 5W S1-LFP-5W-*12VDC 118 LUX at 5m Flameproof Spotlight 7W S1-LFP-7W-*230VAC 125 LUX at 5m Flameproof Floodlight 12W S1-LFP-12W-*12VDC 190 LUX at 5m S1-LFP-12W-*230VAC Flameproof Floodlight 12W 12V
*Add colour: ●R (Red), ●A (Amber), ●G (Green), C (Clear) Zone 1 & Zone 2 Zone 21 & 22 EXD 11
EX Terminal Box for S1 Lights - Optional for S1 Spotlight Code
TBOX-S1
TBOX-S1 Ex d1 T4
Description
Code
1 x M20 1 x M20 1 x M20 1 x M20
Ø8
Description
195 x 171 x 166 195 x 171 x 166 245 x 171 x 180 245 x 171 x 180 60
EX Terminal Box
Flameproof Area Flasher with Battery Backup - 12VDC
S2
28mA 72mA 97mA 111mA
83
Cable Watts Entry
S2-FLP-R12VDC Red Flasher Unit 12VDC c/w Battery Backup 20W
215mm max OD with Foot & Push Button
3 x M20
Size (mm) Øx H
152 x 171
Flameproof Flasher / Siren Combo - 8 different settings, flashings, 3 speed rotating, 4 strobe settings Size (mm) Description Code Watts Øx H Red Flasher/Siren Combo Flameproof 7.5W / 10W 140 x 259.5 S3-CFLP-R*
Ex d1 T4
S3-CFLP-BL*
S3-CFLP-GN* S4-SFLP*
S3
Blue Flasher/Siren Combo Flameproof
Green Flasher/Siren Combo Flameproof Flameproof Siren Only 95dB
7.5W / 10W
140 x 259.5
7.5W / 10W
140 x 259.5 140 x 259.5
*Add voltage to code: 24 for (24/12VDC), 220 for (110/220VAC)
Flameproof Flashers with Keyswitch - c/w keyswitch body, lock & keys
Ex d1 T4
Description
Watts
S5-KFLP-R*
Flasher Unit with Keyswitch Red
7.5W / 10W
140 x 252
Flasher Unit with Keyswitch Green
7.5W / 10W
140 x 252
7.5W / 10W
140 x 252
Size (mm) Ø x L
Flasher Unit with Keyswitch Blue S5-KFLP-BL* *Add voltage to code: 24 for (24/12VDC), 220 for (110/220VAC)
S5
Size (mm) H x L
Code S5-KFLP-GN*
Flameproof Flasher Units - 160mm Max OD with Foot
Ex d1 T4
S6
S6
Code
Description
Watts
S6-FLP-R* S6-FLP-BL* S6-FLP-GN* S6-FLP-WH*
Red Flasher Units
7.5W / 10W
Blue Flasher Units
Green Flasher Units White Flasher Units
*Add voltage to code: 24 for (24/12VDC), 220 for (110/220VAC)
Flameproof Timer Light - 160mm Max OD with Foot S6
S7
S7-TFP-R-24 S7-TFP-A-24 S7-TFP-GN-24
Flameproof resin timer light Red 12/24VDC Flameproof resin timer light Amber 12/24VDC Flameproof resin timer light Green 12/24VDC
128 x 120 128 x 120
7.5W / 10W
128 x 120
7.5W / 10W 7.5W / 10W
128 x 120
7.5W 7.5W 7.5W
128 x 120 128 x 120 128 x 120
LED EXPLOSION PROOF EMERGENCY LIGHT FITTING IP65
Zone 1 & 2 Zone 21 & 22 EXD 11
40W LED-Emergency Light Code BAJ52-20 Specifications
Size
340 x 300 x 125mm
• 6V, 6Ah NI-MH Battery • Charge Time 24H
• 2 x 20W LED • EMG Time 90min
19
M20x1.5 - 6H M20x1.5 - 6g
Ø80
5W, 7W
Power Cable Size (mm) mA Entry H x W x L
33
Ex d II C T4-Gb Ex d I 150°C Mb
FLP
Volts
220 - 240VAC
FLAMEPROOF VEHICLE LIGHTS
Code
Description
*Add Voltage to Code Power
Size (mm) Area
S312LEDR-6-* FLP Mini Light
*Add Voltage to Code Power
Size (mm)
FLP Red LED Maxi Reverse Light
FLP Small Head Light
12(12VAC/DC) or 24(24VAC/DC) 12(12VAC/DC) or 24(24VAC/DC) 15W
Voltage: 12/24VDC
15W
Ø112 x 112L x 120H
15W
Ø140 x 165L x 186W
Ex d I/IIC T4 / Zone 1/21/22
Code
Description
HDLT24-15W
S316LEDR-6-*
Ø112 x 148H
Ex d I/IIC T4 / Zone 1
HFRL-*-*
Ex d I/II B
Ø160 x 140L
Power
222L x 195H x 155W
Ø133 x 223L x 170W
NON-FLAMEPROOF VEHICLE LIGHTS 4500K 680lm
EHL-4LED
4 x 3W LED Lamp 12 - 36VDC 9W
EHL-6LED
6 x 3W LED Loco Lamp 12 - 36VDC 12W
Ø150 x 60H Ø70 x 80H Size (mm) *Add colour to code: ● R (Red), ● GR (Green), ● B (Blue), ● A (Amber - For FEL-Range Only)
Description Voltage
Size (mm) Area
Ranges
CSS-TRIP
FLP Coal Tip Trip Switch 1NO 10A@250VAC Ø150 x 165H
Ex d I/IIC T4 / Zone 1 -
OPS/DM1-*-*
FLP Oil Pressure Switch 1NO 10A@250VAC Ø68 x 160L x 103H
Ex d I/IIC T4 / Zone 1 * Add Pressure to code: 10(1-10bar), 20(10-20bar), 1(0.1-1bar). * Add Contact Type to code: NO, NC
FLP
Ex d I/IIC T4
Thread Size: 25mm
EHL-FEL-*
EHL-STB-*
Ø70 x 80H
Ø90 x 70H
Round LED Marker Lamp 12 - 36VDC 4.2W
FLAMEPROOF SWITCHES
Code
Ex d I/II B
FLP 5 Tone Siren
Ex d I/IIC T4 / Zone 1/21/22
Ex d I/IIC T4 / IP65
6500K 450lm
Voltage
30W
Ø139 x 172H
FLP Siren Flasher Combo
*Add colour to code: ● W (White), ● R (Red), ● GR (Green), ● B (Blue), ● A (Amber)
Description
Voltage: 12/24VDC
36V (9-36VAC/DC) or 250V (75-250VAC/DC) 36V (9-36VAC/DC) or 250V (75-250VAC/DC) 36V (9-36VAC/DC) or 250V (75-250VAC/DC) 5W / 108dB 3W 3W / 108dB
Area
Code
FLP Large Head Light
HSHC-*
HAFC-*-*
FLP Rotating LED Flasher
HDLT24-30W
Strobe Light 12 - 36VDC 7.6W
FLASHER
Non-Flameproof
LS4-*
FLP Level Switch
1NO 10A@250VAC
550/1000/1500/2000
Ex d I/IIC T4 / Zone 1 * Add Size (mm) to code: 550, 1000, 1500, 2000
EHL-REC-*
Rectangular Flasher 12 - 36VDC / 2.7W
200L x 40H x 22D *Add colour to code: ● R (Red), ● GR (Green), ● B (Blue), ● A (Amber), ● W (White), R/G (Red & Green Combined to be switched separately)
20
FLAMEPROOF SIRENS & BEACONS Flameproof Motorised Sirens
• Application: Class 1, 2 & 3 all groups. Division 1 and 2 areas
Code †
Mono & Duplo
Duty Cycle 1min on, 8min off 115VAC
EP500*
EP500 EP1500
Operating Voltage Range
Frequency (Hz)
Max Current at Rated Voltage (A)
*Duty Cycle - Continuous 2 1200
Audible Range
Min Sound at Rated Voltage (dB@1m)
1000m
113 - Ex Duplo
EP500*
230VAC
1200
1
1000m
113 - Ex Duplo
EP500†
12VAC/DC
1200
9
1000m
113 - Ex Mono
24VAC/DC
1200
4.8
1000m
113 - Ex Mono
EP500†
Duty Cycle 30min on, 10min off
EP1500
115VAC
1600
2.6
1500m
126
230VAC
1600
2.1
1500m
126
EP2000
115VAC
370/660
4.0
2000m
128
230VAC
370/660
3.0
2000m
128
EP1500 EP2000
EP2000
Flameproof Electronic Sounder
• Maintenance free solid state sounder • Four sounds from one unit for different applications • High sound output with volume control • Application: Class 1, 2 & 3 all groups. Division 1 and 2 areas
EXS Multi Sounder
• High quality steel casting, precision engineered • Rugged multipurpose weatherproof device • Application: Class 1, 2 & 3, all groups. Division 1. 1 and 2 areas
Xenon & LED
Code
Description
Sound Output @1m
EXS*
Flameproof Multi Sounder
93-113dB
*Add voltage: 12VDC, 24VDC, 115VAC, 230VAC
Flameproof Beacon - Xenon Strobe Code Description Flameproof Beacon EXF-A* Flameproof Beacon EXF-B* Flameproof Beacon EXF-G* Flameproof Beacon EXF-R* Flameproof Beacon - LED Type Flameproof Beacon EXFL-A* Flameproof Beacon EXFL-R* Flameproof Beacon EXFL-G*
*Add voltage: 12VDC, 24VDC, 110VAC, 230VAC
Colour
FPM
Light
● Amber ● Blue ● Green ● Red
110 110 110 110
Xenon Tube Xenon Tube Xenon Tube Xenon Tube
● Amber ● Red ● Green
110 110 110
LED LED LED
Flameproof Beacon and Sounder Combination - Xenon Strobe Light Code Colour Description
Multi Sounder & LED Beacon Multi Sounder & Xenon Tube
EXCX*
Xenon Tube Flameproof Sounder and Beacon ● Amber EXCX-A* Xenon Tube Flameproof Sounder and Beacon ● Blue EXCX-B* Xenon Tube Flameproof Sounder and Beacon ● Green EXCX-G* Xenon Tube Flameproof Sounder and Beacon ● Red EXCX-R* Flameproof Beacon and Sounder Combination - LED Type LED Flameproof Sounder and Beacon ● Amber EXCL-A* LED Flameproof Sounder and Beacon ● Green EXCL-G* LED Flameproof Sounder and Beacon ● Red EXCL-R* *Add voltage: 12VDC, 24VDC, 115VAC, 230VAC
Colours
21
FLP
FPM 110 110 110 110 110 110 110
EXPLOSION PROOF EQUIPMENT IP66 E2S Flameproof Manual Call Points Description
Duty Cycle
Voltage
EX Break Glass Call Point
Continuous Rated
24VDC
-
-
Continuous Rated
24VDC
Continuous Rated EX Tool Reset Call Point Housing Material: Marine grade copper free LM6 Aluminium
24VDC
Code
ECPG003 ECPG002
Call Point Spare Glass
ECPP002 ECPG003
ECPP002
EX Push Button Call Point
ECPT002
ECPT002
FLAMEPROOF SIRENS & BEACONS IP67 EX11 Flameproof Sounders
EXS1012
Duty Cycle
Sound Output
Current Consumption
Tone
110db
250mA
32 Tone
Code
Description
EXS1012 EXS1024 EXS1110 EXS1220
EX 11 Sounder 12VDC
EXS2012 EXS2024 EXS2110 EXS2220
EX 12 Sounder 12VDC
Continuous Rated
120db
850mA
EX 12 Sounder 110VAC
Continuous Rated
120db
180mA
Code
Description
EXB051*
EX 05 Beacon 12VDC
Continuous Rated
110db
Continuous Rated
110db
Continuous Rated
EX 11 Sounder 24VDC
EX 11 Sounder 110VAC
Continuous Rated
EX 11 Sounder 220VAC
110db
195mA 110mA
32 Tone
56mA
32 Tone
EX12 Flameproof Sounders
EXS2012
EX 12 Sounder 24VDC
Continuous Rated
EX 12 Sounder 220VAC
Continuous Rated
EX 05 Flameproof Beacons
32 Tone
90mA
32 Tone
Continuous Rated
Xenon Tube
EX 05 Beacon 24VDC
Continuous Rated
Xenon Tube
5 Joule @ 1Hz
EX 05 Beacon 110VAC
Continuous Rated
Xenon Tube
5 Joule @ 1Hz
EX 05 Beacon 220VAC
Continuous Rated
Xenon Tube
5 Joule @ 1Hz
EXB101*
EX 10 Beacon 12VDC
Continuous Rated
Xenon Tube
10 Joule @ 1Hz
Continuous Rated
Xenon Tube
EXB103*
EX 10 Beacon 24VDC EX 10 Beacon 110VAC
Continuous Rated
Xenon Tube
EX 10 Beacon 220VAC
Continuous Rated
Xenon Tube
10 Joule @ 1Hz
EX 15 Beacon 12VDC
Continuous Rated
Xenon Tube
15 Joule @ 1Hz
EX 15 Beacon 24VDC
Continuous Rated
Xenon Tube
15 Joule @ 1Hz
EX 15 Beacon 110VAC
Continuous Rated
Xenon Tube
15 Joule @ 1Hz
EX 15 Beacon 220VAC
Continuous Rated
Xenon Tube
15 Joule @ 1Hz
EXB054*
Duty Cycle
EX 10 Flameproof Beacons
EXB102* EXB104*
EX 15 Flameproof Beacons
EXB151* EXB152* EXB153*
EXB151
32 Tone
Light Output
EXB053*
EXB101
120db
32 Tone
800mA
Light Source
EXB052*
EXB051
120db
32 Tone
EXB154*
5 Joule @ 1Hz
10 Joule @ 1Hz 10 Joule @ 1Hz
*Add colour: ●R (Red), ●A (Amber), ●G (Green), ●B (Blue)
EX 1105 Flameproof Beacons/Sounder Combo Duty Description Code Cycle Continuous EX 1105 Combo 12VDC EXC111* Continuous EXC112* EX 1105 Combo 24VDC Continuous EX 1105 Combo 110VAC EXC113* EXC111 EXB114* EX 1105 Combo 220VAC Continuous
Sound Output
110db 110db 110db 110db *Add colour: ●R (Red), ●A (Amber), ●G (Green), ●B (Blue)
Current Consumption
195mA 250mA 110mA 56mA
Light Source
Xenon Tube Xenon Tube Xenon Tube Xenon Tube
Light Output
5 Joule @ 1Hz 5 Joule @ 1Hz 5 Joule @ 1Hz 5 Joule @ 1Hz
Tone 32 Tone 32 Tone 32 Tone 32 Tone
Flameproof Hand Operated Siren Code H200CAGE
Frequency 500Hz
Audible Range 2000m
FLP
dB @ 1m 120
Duty Cycle 100%
IP Rating IP44
22
EXPLOSION PROOF SIRENS & BEACONS Flameproof Sounders and Beacons
• Application: Class 1, 2 & 3 all groups. Division 1 and 2 areas
XB8
DB5
Material
Max Current at Rated Voltage (A)
Min Sound at Rated IP Voltage Rating (dB@1m)
Tone
24VDC
ABS
14mA
100
IP65
26 Tone
24VDC
Polyester
34mA
103
IP66
27 Tone
24VDC
Polyester
55mA
60F/M
IP66
Beacon
Code
Operating Voltage Range
DB5 DB7 XB8
Manual Callpoint IP67 Code BG2 DB7
BG2
Description
Switch Ratings: 0 to 30VDC – 5A (resistive) or 3A (inductive); 30 to 50VDC – 1A (resistive) or 3A (inductive); 0 to 254VAC – 5A (resistive) or 3A (inductive). Material: UV resistant glass reinforced polyester.
Explosion Proof Signal Horn EXH 24VAC
24VAC
PC/ABS
450mA
105
IP55
Horn
115VAC
PC/ABS
205mA
105
IP55
Horn
230VAC
PC/ABS
70mA
105
IP66
Horn
230VAC
Aluminium
70mA
110
IP55
Siren
GR3T 115VAC 115VAC
Aluminium
150mA
110
IP55
Siren
Aluminium
160mA
109
IP55
Siren
EXH 115VAC
EXH 230VAC
Flameproof Siren GR3T 24VAC GR3T 24V
12-24VAC/DC
Above Sirens 100% continuous rated
Aluminium Explosion Proof Beacon IP66 Xenon Tube
GR3T
Code FHL113-A* FHL113-R*
FHL113-G*
Colour
FPM
Connection
● Red
110
3/4 inch
● Green
110
3/4 inch
110
● Amber
*Add Voltage 24V (12-24VAC/DC), 110VAC, 230VAC
3/4 inch
Spare PCB c/w Xenon Tube 113/FH-PCB
FHL113
12/24VAC/DC P.C.B c/w Xenon Tube
113/FH-PCB 110V
110V P.C.B c/w Xenon Tube
113/FH-PCB 230V
230V P.C.B c/w Xenon Tube
Sounders Intrinsically safe zone 0, 1 & 2 Gas Group 11C
E2SIS
E5YIS
Code
Operating Voltage Material Range
E2SIS
24VDC
E5YIS
24VDC
Beacons E2BIS-*
24VDC
Max Current at Rated Voltage (A)
113/FH-PCB 230V
Min Sound IP at Rated Rating Tone Voltage (dB@1m)
ABS Flame retardant 25mA UL94VO ABS Flame retardant 93mA UL94VO
100
IP65
49 Tone
105
IP66
32 Tone
ABS Flame retardant 25mA UL94VO
–
IP65
Beacon
100
IP65
49 Tone
*Add colour: ●R (Red), ●A (Amber), ●G (Green), ●B (Blue)
Sounder/Beacons 24VDC E25BIS-*
E2BIS
23
E25BIS
ABS Flame retardant 48mA UL94VO *Add colour: ●R (Red), ●A (Amber), ●G (Green), ●B (Blue)
FLP
LED EXPLOSION PROOF BEACONS IP65 Beacon / Sounder - ≥80dB
Beacon II 2G Exd II CT6
II 2G Exd [ib] ib II CT6
Code
Colour
BBJ-ZG-* ● Green BBJ-ZR-* ● Red BBJ-ZY-* ● Yellow BBJ-ZB-* ● Blue *Add voltage to code: 110VAC, 230VAC • LED lamp, low energy consumption, long service life • IP-Rating IP65 • Flash frequency: 150/min • Cable entry c/w cable seal-ring and locking device
Code
Colour
BJD-ZG-* BJD-ZR-* BJD-ZY-* BJD-ZB-*
● Green ● Red ● Yellow ● Blue
• Ideally suited for use in IIA, IIB and IIC areas. • Glass cover resistant to temperature changes • Housing in aluminium alloy, powder-coated • Suitable for use in Zones 1 & 2
EXPLOSION PROOF ANALOGUE ULTRASONIC LEVEL DETECTION For continuous no-contact level measurement of various liquid and bulk solid materials in closed or open vessels, sumps, reservoirs etc.
Sensing Distance
Output Type
0,2 - 2m 0,25 - 6m 0,4 - 10m Explosionproof Field Adjustable Type - Must be used with IRU-420 (Below) c/w Connector Socket 4 - 20mA (2-Wire) EX Rating
Mounting Type Supply Voltage Accuracy Ambient Temperature
ULM-53XI-02-I
Suitable for explosive areas (combustible gases or vapours) II 1/2G Ex ia IIB T5 with isolating repeater (IRU–420) the whole level meter – zone 1, front head part – zone 0
G1"
ULM-53XI-06-I
Suitable for explosive areas (combustible gases or vapours) II 1/2G Ex ia IIB T5 with isolating repeater (IRU–420) the whole level meter – zone 1, front head part – zone 0
-30° to 70°C
Code
TM
ULM-53XI-20-I
Suitable for explosive areas (combustible gases or vapours) II 2G Ex ia IIA T5 with isolating repeater (IRU–420) the whole level meter – zone 1
Aluminium Alloy Flange
-30° to 60°C
Wiring Diagram
Isolating Repeater - for use with ULM-53XI Input Signal Output Signal Bi-directional Trans Comms Signal HART
ULM-53XI-10-I
Suitable for explosive areas (combustible gases or vapours) II 1/2G Ex ia IIA T5 with isolating repeater (IRU–420) the whole level meter – zone 1, front head part – zone 0
Polypropylene 18 - 36VDC 0.20%
G1½"
Dimensions
0,5 - 20m
IRU-420-I-* 0/4 - 20mA 0/4 - 20mA NO
IRU-420-H-* 4 - 20mA 4 - 20mA YES
IRU-420-U-* 4 - 20mA 4 - 20mA NO
*Add Voltage to Code: 24V (18-30VAC/18-40VDC) 230V (60-230VAC/85-230VDC) II(1)G[EEx ia] IIB /IIC I(M1)G[EEx ia] I
FLP
24
COMMUNICATION EQUIPMENT Explosion Proof
Robust Telephones
Zenith
Ratel
Phoenix
Z500
A120
A130
IP65 260 x 120 x 100mm ABS 1Kg
Weatherproof 230 x 140 x 110mm M/Steel Powder Coated 2.5Kg
Double Protection 280 x 15 x 140mm Gun Metal Brass 9Kg
Code Rating Size (HxWxD) Housing Weight
ABS Weatherproof IP54
Ex d I/II B + H2 T6/ Ex m e [ia]I/II C T6
Automatic analogue industrial/mining telephone compatible with all 24V/48V PABX systems, pulse/tone switchable. Ring signal 45V-90VAC 17Hz-50Hz
Code
I430-ICE
I448
I430-ICE
Size: 310 x 220 x 130. Single Telephone Cable Pair, 2-80 telephone. Line Voltage: 48VDC. Distance: 10-12km. Max 80 phones per power supply.
Code
I448
110/230-48VDC Power supply to be ordered separately with 48hr battery back up included
Telephone Extension Light/Siren
Telephone Booths
Phone Ringer. For standard 2 wire analogue phones only.
SSLU
Acoustic
Code
ATB100
Size (HxWxD) Housing Weight
Non Acoustic
670 x 500 x 450mm Fibreglass 7.5Kg
TB100
670 x 450 x 500mm Polypropylene 5Kg
Weatherproof IP65 340 x 140 x 120 ABS 3Kg • Operates in sympathy with the telephone ring signal. • Powered by 110 or 220VAC • Siren 116db o/p. • Light 8 x super bright LED.
Light & Siren Unit
PAGE TELEPHONES
Page Telephones Code
P300NHT P300
P300
No Handset Weatherproof IP65 Rating 310 x 140 x 120mm Size (HxWxD) ABS Housing 3kg Weight • 2-50 telephones connect in parallel with twisted telephone cable pair • Operates on 230VAC/ 110VAC • Central 12V PSU option available • Simplex, open voice comms at 2 watt output
P300NHT
Yes Weatherproof IP65 310 x 140 x 120mm ABS 3.5kg
EX HOWL CALL TELEPHONE BOOTHS
Ex Howl Telephones - without power supply.
Sound-powered telephone systems for use in rough conditions, including areas with explosive atmospheres and fire-damp.
Code 5069
Description
Howl-Call Telephone without snap-in plug
Application - If you want or need to telephone in areas where this is normally not possible, you need a sound-powered telephone system. Operation without external power supply and complex equipment, sound-powered telephones are ideal for communications
whenever there is no power supply available, e.g. at blast furnaces, in tunnelling or mining, or offshore on oil rigs or high-sea steamers, and provide a direct connection to the switchboard, base, bridge or colleagues on the surface or wherever. This surprisingly easy, but effective method is already used widely to call for material, report faults or save lives.
25
FLP
NOTES
FLP
26
AC/DC SFC FLAMEPROOF